Severe pacemaker lead perforation detected by an automatic home-monitoring system.
نویسندگان
چکیده
Kirma C. Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study. Int J Cardiol 2005; 102:127–136. 18. Abraham TP, Belohlavek M, Thomson HL, Pislaru C, Khandheria B, Seward JB, Pellikka PA. Time to onset of regional relaxation: feasibility, variability and utility of a novel index of regional myocardial function by strain rate imaging. J Am Coll Cardiol 2002;39:1531–1537. 19. Kowalski M, Kukulski T, Jamal F, D’Hooge J, Weidemann F, Rademakers F, Bijnens B, Hatle L, Sutherland GR. Can natural strain and strain rate quantify regional myocardial deformation? A study in healthy subjects. Ultrasound Med Biol 2001;27:1087–1097. 20. Weidemann F, Jamal F, Sutherland GR, Claus P, Kowalski M, Hatle L, De Scheerder I, Bijnens B, Rademakers FE. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am J Physiol Heart Circ Physiol 2002;283:H792–H799. 21. Jamal F, Kukulski T, Strotmann J, Szilard M, D’Hooge J, Bijnens B, Rademakers F, Hatle L, De Scheerder I, Sutherland GR. Quantification of the spectrum of changes in regional myocardial function during acute ischemia in closed chest pigs: an ultrasonic strain rate and strain study. J Am Soc Echocardiogr 2001;14:874–884. 22. Topol EJ, Ellis SG, Cosgrove DM, Bates ER, Muller DW, Schork NJ, Schork MA, Loop FD. Analysis of coronary angioplasty practice in the United States with an insurance-claims data base. Circulation 1993;87: 1489–1497. 23. Chaitman BR, Bourassa MG, Davis K, Rogers WJ, Tyras DH, Berger R, Kennedy JW, Fisher L, Judkins MP, Mock MB, Killip T. Angiographic prevalence of high-risk coronary artery disease in patient subsets (CASS). Circulation 1981;64:360–367.
منابع مشابه
Case report: Pacemaker lead perforation of a papillary muscle inducing severe tricuspid regurgitation
INTRODUCTION We report a rare but severe pacemaker complication of a pacemaker lead perforating the papillary muscle. This induced severe tricuspid regurgitation and right heart failure. Patients suffering from right heart failure have an increased operative risk of open-heart surgery and therefore represent a clinical challenge due to the lack of clear guidelines. CASE PRESENTATION A 70-year...
متن کاملAutomatic remote home monitoring of implantable cardioverter defibrillator lead and generator function: a system that tests itself everyday.
The implantation of cardiac electronic devices (CIEDs) has increased exponentially over the last decade in response to widening indications. Assessment of post-implant system performance is an important responsibility but challenging in view of increasing volume, device complexity, and advisory notices. Automatic remote home monitoring (HM) may satisfy these difficult monitoring demands. When t...
متن کاملIdentification and management of right ventricular perforation using pacemaker and cardioverter-defibrillator leads: A case series and mini review
Right ventricular perforation is a rare but serious complication of permanent pacemaker and implantable cardioverter-defibrillator implantation, with a reported prevalence rate of 0.1-6%. Generally, there is a high incidence of asymptomatic lead perforation with otherwise normal function. Some patients present with a stabbing chest pain and shortness of breath or pacemaker malfunction. However,...
متن کامل[Pacemaker lead-induced tricuspid stenosis: a report of two cases].
Tricuspid stenosis (TS) is an uncommon complication of transvenous ventricular pacemaker implantation, with few cases reported in the literature. The mechanisms described are obstruction of right ventricular inflow by tricuspid vegetations (endocarditis), multiple pacemaker leads and tricuspid valve (TV) fibrosis secondary to perforation or laceration of the TV leaflets, or adherence between re...
متن کاملThree-dimensional echocardiographic documentation of pacemaker lead perforation presenting as acute pericarditis.
Myocardial perforation is a rare complication of permanent pacemaker insertion and is usually detected during the first month after implantation. Pericardial effusion often occurs at the same time, and as a consequence may generate difficulties in the diagnostic workup due to the various aetiologies of its origin. Computed tomography has been used for the documentation of lead perforation, but ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal
دوره 28 12 شماره
صفحات -