Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma.

نویسندگان

  • D S Kamal
  • A C Viswanathan
  • D F Garway-Heath
  • R A Hitchings
  • D Poinoosawmy
  • C Bunce
چکیده

AIM To determine whether analysis of sequential optic disc images obtained with the Heidelberg retina tomograph (HRT) is able to demonstrate optic disc change before the development of reproducible field defects in a group of ocular hypertensive (OHT) patients converting to early glaucoma. METHODS Two groups were analysed: (1) 13 eyes of 13 OHT patients who subsequently developed reproducible field defects (converters); and (2) 13 eyes of 11 normal control subjects. Two sequential optic disc images were obtained using the HRT (median separation between images was 12 months for the converters and 13 months for the normals). The second image in the converter group was obtained before confirmed visual field loss. The optic disc variables were analysed both globally and segmentally using HRT software version 1.11. The Wilcoxon signed rank test was used to determine if there were any significant differences between the variables of the two image sets. RESULTS Significant optic disc change was demonstrated in the group of converters: (1) global variables: the cup area increased by 9.7%, the C/D area ratio increased by 10.5%, and the rim area decreased by 6.9%; (2) segmental variables: the superonasal cup area increased by 11.0%, the superonasal C/D area ratio increased 11.7%, and the inferonasal cup volume increased by 28.4%. The temporal rim volume decreased by 15.6%, the inferotemporal rim volume decreased by 23.6%, and the rim area in the superonasal and superotemporal segments decreased by 6.6% and 6.9% respectively. CONCLUSION Analysis of sequential optic disc images on the HRT allowed the detection of glaucomatous change before confirmed visual field change in a group of OHT patients converting to early glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of sequential Heidelberg retina tomograph images to identify changes at the optic disc in ocular hypertensive patients at risk of developing glaucoma.

AIM To determine if global and segmental changes in optic disc parameters of sequential Heidelberg retina tomograph (HRT) images develop in individual ocular hypertensive (OHT) patients without white on white visual field defects. METHODS Patients and normal controls were recruited from a prospective ocular hypertension treatment trial. The subject groups consisted of 21 OHT patients who had ...

متن کامل

A Bayesian framework for glaucoma progression detection using Heidelberg Retina Tomograph images

Glaucoma, the second leading cause of blindness in the United States, is an ocular disease characterized by structural changes of the optic nerve head (ONH) and changes in visual function. Therefore, early detection is of high importance to preserve remaining visual function. In this context, the Heidelberg Retina Tomograph (HRT), a confocal scanning laser tomograph, is widely used as a researc...

متن کامل

Scanning laser ophthalmoscopy of the optic nerve head in exfoliation glaucoma and ocular hypertension with exfoliation syndrome.

AIMS To study the relation between optic nerve head topography (Heidelberg retina tomograph, HRT) and disc area, visual field index mean defect (MD), and intraocular pressure (IOP), and to see whether change in HRT parameters is associated with change in MD in a prospective follow up. METHODS 80 consecutive patients (69 patients with exfoliation glaucoma and 11 with ocular hypertension combin...

متن کامل

Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension.

AIM To compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT). METHODS One hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as n...

متن کامل

False negative results in glaucoma detection with Heidelberg Retina Tomograph II

PURPOSE To evaluate the rate of false negative results with the Heidelberg Retina Tomograph (HRT II) in a glaucoma practice. DESIGN Cross-sectional study. METHODS We analyzed the HRTs taken between October 2002 and October 2003 in our glaucoma clinic, and selected the patients who had a good quality image (SD < 40 mu) with a normal Moorfield's Regression Analysis (MRA). A masked independent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 3  شماره 

صفحات  -

تاریخ انتشار 1999