Delayed fracture of MatrixRIB precontoured plate system.
نویسندگان
چکیده
OBJECTIVES Use of titanium prostheses for reconstructing chest wall defects following major chest wall resections is rapidly increasing in popularity. Previously, complications including prosthesis fracture have been reported for the system secured to the rib ends using clips following chest wall reconstruction and pectus excavatum repair. By contrast, fracture failure in titanium systems fastening the plate to the rib with locking screws through predrilled holes has not been previously reported, possibly owing to differences in the design and material of the system. METHODS We report an index case of plate fracture in the latter design following rib reconstruction and discuss the pathophysiology and relative risks behind such fractures. RESULTS Fracture of titanium plate occurred after chest impact during sport at 25 months following initial plate implantation. Surgical excision was performed because of persistent pain and cough. CONCLUSIONS Fracture failure can occur in those systems fastening the plate to the rib with locking-screws, and patients, particularly those engaged in contact sports or occupations with chest impact risks, should be informed of this possibility during consent, as surgical removal is most likely required following implant fracture failur.
منابع مشابه
Evaluation of prominence of straight plates and precontoured clavicle plates using automated plate-to-bone alignment.
Hardware prominence after plate fixation for clavicle fracture is a common complication. The aim of the study was to perform a 3D analysis of the prominence of different types of superior clavicle plates. An automated fitting of 3 straight and 10 precontoured plates was performed on 52 3D-CT-scan reconstructed cadaver clavicles. The mean and maximum bone-plate distance and maximum prominence wa...
متن کاملAnatomically precontoured LCP for delayed union of a medial third clavicle fracture. Case report with review of the literature.
BACKGROUND Fractures of the medial clavicle third are rare injuries. Even in case of significant fracture displacement, their therapeutic management has been nonoperative. Recently, surgical intervention has become mandatory for displaced fractures types to prevent non-union and functional complaints, but the optimal operative strategy is being discussed controversially. CASE PRESENTATION We ...
متن کاملPrecontoured locking plate fixation for displaced lateral clavicle fractures.
Displaced fractures of the lateral end of the clavicle are associated with an increased risk of nonunion with conservative treatment; therefore, operative treatment is recommended. Various operative treatments have been suggested, but no consensus exists regarding a gold standard for the surgical treatment of this type of fracture. The purpose of this study was to evaluate clinical and radiolog...
متن کاملComparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures.
Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking com...
متن کاملExtrinsic Subclavian Vein Compression after Osteosynthesis of a Midshaft Clavicular Fracture in an Athlete
Clavicle fractures are common injuries. Traditionally, nonsurgical management has been favored; however, recent evidence has emerged indicating that operative fixation produces lower nonunion rates, better functional outcomes, improved cosmesis, and greater patient satisfaction. Although clavicle fixation has been considered a safe procedure, several complications related to plate fixation have...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2014