omparison of the chromatography of octadecyl silane bonded silica and polybutadiene-coated zirconia phases based on a diverse set of cationic drugs
نویسندگان
چکیده
In this study, we compare the separation of basic drugs on several octadecyl silane bonded silica (ODS) phases and a polybutadiene-coated zirconia (PBD–ZrO ) phase. The retention characteristics were investigated in detail using a variety of 2 cationic drugs as probe solutes. The ODS phases were selected to cover a relatively wide range in silanol activity and were studied with ammonium phosphate eluents at pH 3.0 and 6.0. Compared to any of the ODS phases, the PBD–ZrO phase 2 showed very significant differences in selectivities towards these drugs. Due to the presence of both reversed-phase and ion-exchange interactions between the stationary phase and the basic analyte on ODS and PBD–ZrO , mixed-mode retention 2 takes place to some extent on both types of phases. However, very large differences in the relative contributions from ion-exchange and reversed-phase interactions on the two types of phases led to quite different selectivities. When phosphate is present in the eluent and adsorbs on the surface, the PBD–ZrO phase takes on a high negative charge over a wide pH 2 range due to phosphate adsorption on its surface. On ODS phases, ion-exchange interactions result from the interactions between protonated basic compounds and ionized residual silanol groups. Since the pH of the eluent influences the charge state of the silanol groups, the ion-exchange interactions vary in strength depending on pH. At pH 6.0, the ion-exchange interactions are strong. However, at pH 3.0 the ion-exchange interactions on ODS are significantly smaller because the silanol groups are less dissociated at the lower pH. Thus, not only are the selectivities of the ODS and PBD–ZrO phases 2 different but quite different trends in retention are observed on these two types of phases as the pH of the eluent is varied. More importantly, by using the large set of ‘‘real’’ basic analytes we show the extreme complexity of the chromatographic processes on the reversed stationary phases. Both the test condition and solute property influence the column performance. Therefore, use of only one or two probe solutes is not sufficient for column ranking. 2003 Elsevier B.V. All rights reserved.
منابع مشابه
A comparative study of the chromatographic selectivity of polystyrene-coated zirconia and related reversed-phase materials.
The chromatographic selectivities of polystyrene-coated zirconia (PS-ZrO2) have been investigated in detail by means of homologue series retention studies and studies of a variety of nonpolar aromatic positional isomers. This material has been compared to polybutadiene-coated zirconia, octadecyl- and phenyl-bonded silica, and polymer-based reversed phases. In addition, the separations of a wide...
متن کاملبررسی تأثیر روشهای پوششدهی مختلف بر استحکام باند رزین به زیرکونیا
Objective: A clinical challenge of using zirconia frameworks is to achieve adequate bond with different substrates. This study aimed to evaluate the effect of bioglass and silica coating of zirconia substrates on microshear bond strength of resin cement to tetragonal zirconia. Methods: This laboratory experimental study was conducted on zirconia discs. A total of 120 YTZP zirconia (Zirkonzahn) ...
متن کاملDetermination of inorganic anions by capillary ion-exchange chromatography using polyethylenimine-coated octadecyl-bonded phases.
The utility of a cationic polymer polyethylenimines (PEI) for coating some commercially available silica-based stationary phases packed in capillaries of 0.32 mm i.d. and 10 cm long was studied for the separation and direct UV detection of inorganic anions (iodate, bromate, nitrite, bromide, and nitrate ions). With a super-endcapped octadecylated silica stationary phase, which yielded the best...
متن کاملEvaluation of Factors Inf luencing Recovery of Herbicide 2,4-D from Drinking Water
Many modern analytical methods deal with the trace-level determination of compounds of interest in highly complex environmental samples by means of chromatographic techniques. The introduction of a “clean” sample into an analytical instrument can make analyses easier and prolongs the equipment life. The use of solid-phase extraction (SPE) has grown and is a fertile technique of sample prepa...
متن کاملStability of silica-based, endcapped columns with pH 7 and 11 mobile phases for reversed-phase high-performance liquid chromatography.
The goal of this study was to define practical conditions and limitations of using silica-based, endcapped bonded-phase columns in intermediate and higher pH environments for developing rugged HPLC methods. Bonded-phase degradation in this pH range is a result mainly of silica support dissolution; covalently-bound silane ligands are hydrolyzed very slowly if at all from silica supports at inter...
متن کامل