Early clinical experience with the On-X prosthetic heart valve.

نویسندگان

  • A Laczkovics
  • M Heidt
  • H Oelert
  • G Laufer
  • H Greve
  • J L Pomar
  • F W Mohr
  • A Haverich
  • D Birnbaum
  • D Regensburger
  • G Palatianos
  • E Wolner
چکیده

BACKGROUND AND AIM OF THE STUDY The study was designed to investigate the clinical performance of the On-X prosthetic heart valve in a multicenter experience. METHODS Between September 1996 and September 1999, 301 patients (56% males) underwent isolated On-X valve replacement (184 isolated aortic (AVR), 117 isolated mitral (MVR)) at 11 European centers under a standardized protocol. Average age at implant was 60.2 years. Office or hospital follow up was required by the protocol; average follow up on all patients was 11 months. RESULTS Thirty-day mortality in the study was 2.2% for AVR and 6.0% for MVR, with valve-related mortality of 0.5% for AVR. There were eight late deaths (0.7%/pt-yr AVR and 2.3%/pt-yr MVR). Two of these deaths were sudden, and thus possibly valve-related (one AVR, one MVR). Early total valve-related morbidity was 3.5% for AVR and 2.6% for MVR. In total, 13 thromboembolic events occurred; one early event in AVR resulted in death (0.5%), and one transient early event occurred in MVR (0.9%). There were 11 late events (seven AVR (1.7%/pt-yr) and four MVR (1.8%/pt-yr)), for a two-year freedom from thromboembolism of 96.6% after AVR and 97.1% after MVR. Three late bleeding events occurred, all after AVR (0.7%/pt-yr and 98.9% free at two years). Major paravalvular leaks requiring reoperation occurred on two occasions early (one AVR (0.5%), one MVR (0.8%)) and once late in MVR (0.5%/pt-yr). Late minor, untreated paravalvular leaks occurred in three AVR patients (0.7%/pt-yr) and in one MVR patient (0.5%/pt-yr). Prosthetic endocarditis occurred four times (two AVR (0.5%/pt-yr), two MVR (0.9%/pt-yr)), all within the first 12 months of surgery. Actuarial freedom from all valve-related events at two years was 88.7% for AVR and 88.1% for MVR. NYHA class was improved in 75.8% of AVR patients and 70.6% of MVR patients at two years after surgery. CONCLUSION These early results indicate that the On-X valve provides satisfactory clinical outcome in the immediate postoperative period, and that the valve is both safe and effective.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

نتایج مفید جراحی قلب در بیماران مبتلا به آندوکاردیت: بررسی 43 بیمار با آندوکاردیت عفونی که تحت عمل جراحی قلب قرار گرفته اند

Two factors changed the clinical course of infective endocarditis dramatically: 1) The discovery and evolution of techniques for identifying and treating its microbiologic causes and 2) Valvular surgery. We retrospectively evaluated 43 (33.5%) patients (8 female, 35 male) from 4 to 65 years old of 128 patients with infective endocarditis who underwent surgical intervention. Indication for surge...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 2001