Accuracy of parents in measuring body temperature with a tympanic thermometer

نویسندگان

  • Joan L Robinson
  • Hsing Jou
  • Donald W Spady
چکیده

BACKGROUND It is now common for parents to measure tympanic temperatures in children. The objective of this study was to assess the diagnostic accuracy of these measurements. METHODS Parents and then nurses measured the temperature of 60 children with a tympanic thermometer designed for home use (home thermometer). The reference standard was a temperature measured by a nurse with a model of tympanic thermometer commonly used in hospitals (hospital thermometer). A difference of >or= 0.5 degrees C was considered clinically significant. A fever was defined as a temperature >or= 38.5 degrees C. RESULTS The mean absolute difference between the readings done by the parent and the nurse with the home thermometer was 0.44 +/- 0.61 degrees C, and 33% of the readings differed by >or= 0.5 degrees C. The mean absolute difference between the readings done by the parent with the home thermometer and the nurse with the hospital thermometer was 0.51 +/- 0.63 degrees C, and 72 % of the readings differed by >or= 0.5 degrees C. Using the home thermometer, parents detected fever with a sensitivity of 76% (95% CI 50-93%), a specificity of 95% (95% CI 84-99%), a positive predictive value of 87% (95% CI 60-98%), and a negative predictive value of 91% (95% CI 79-98 %). In comparing the readings the nurse obtained from the two different tympanic thermometers, the mean absolute difference was 0.24 +/- 0.22 degrees C. Nurses detected fever with a sensitivity of 94% (95 % CI 71-100 %), a specificity of 88% (95% CI 75-96 %), a positive predictive value of 76% (95% CI 53-92%), and a negative predictive value of 97% (95%CI 87-100 %) using the home thermometer. The intraclass correlation coefficient for the three sets of readings was 0.80, and the consistency of readings was not affected by the body temperature. CONCLUSIONS The readings done by parents with a tympanic thermometer designed for home use differed a clinically significant amount from the reference standard (readings done by nurses with a model of tympanic thermometer commonly used in hospitals) the majority of the time, and parents failed to detect fever about one-quarter of the time. Tympanic readings reported by parents should be interpreted with great caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites

A new method recently used for measuring the temperature is using tympanic thermometer. The aim of this study was to compare the accuracy of this method with rectal and axillary measurement in children less than 6 years old. A total of 220 pair ears, axillaries, and rectal sites were used to determine the body temperature in patients aged between 3 months to 6 years who referred to Emergency De...

متن کامل

An evaluation of tympanic thermometry in a paediatric emergency department.

BACKGROUND AND OBJECTIVES The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting. METHOD In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and...

متن کامل

Tympanic versus rectal thermometry in pregnant women.

OBJECTIVE To assess the accuracy of the tympanic membrane thermometer for use with pregnant women. DESIGN Cross-sectional descriptive study. SETTING A major medical center in the midwestern United States. PARTICIPANTS Thirty-three hospitalized, afebrile pregnant women. MAIN OUTCOME MEASURES Tympanic membrane thermometers and glass mercury thermometers were used to measure body temperatu...

متن کامل

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...

متن کامل

Comparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult

      Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Family Practice

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2005