Reproducibility of endothelial assessment during corneal organ culture: comparison of a computer-assisted analyzer with manual methods.
نویسندگان
چکیده
PURPOSE To investigate the reproducibility of endothelial assessment of organ-cultured corneas with the computer-assisted Sambacornea analyzer in comparison with manual METHODS methods. Seven observers of two eye banks determined the endothelial cell density (ECD) of 30 corneas through a grid overlay placed on endothelial photographs using two manual modes, unaided (naked-eye) and pointing (point-out). ECD was measured with the analyzer, first in automated mode, where analysis was completely machine determined, and then in touched-up mode, where the observer selected the analysis zone and corrected poorly drawn cell borders. Interobserver variability of ECD for the different methods was compared. Reproducibility of morphometry parameters was determined for the touched-up mode. RESULTS Interobserver variability was +/-19.2% (95% confidence interval [CI], 13.0-25.4) and +/-17.6% (95% CI, 11.9-23.3) for the naked-eye and point-out mode, respectively, whereas the touched-up mode gave the least variability of +/-9.6% (95% CI, 6.5-12.7), confirmed by the highest intraclass correlation coefficient of 0.95 (95% CI, 0.91-0.97). Interobserver variability increased with worsening image quality. Manual modes underestimated ECD (naked-eye by a mean 10.7% [SD, 2.9%]; point-out by a mean 6.9% [SD, 2.3%]), whereas the automated mode overestimated ECD by a mean 14.7% (SD, 24.3%). Reproducibility of morphometric parameters by the touched-up mode was acceptable but was influenced by endothelial pleomorphism. CONCLUSIONS Manual counting shows systematic underestimation of ECD with high interobserver variability. The analyzer in automated mode overestimates ECD and is absolutely unreliable. Detection of cell contours by the specific algorithm, combined with manual correction by a skilled technician, appears to be the most reliable method of ECD and morphometry determination.
منابع مشابه
Standard microlithographic mosaics to assess endothelial cell counting methods by light microscopy in eye banks using organ culture.
PURPOSE To develop standard microscopic hexagonal mosaics mimicking the human corneal endothelium for quality control of endothelial cell density (ECD) measurement and verification of cell counting strategy by light microscopy in eye banks using organ culture. METHODS A standard slide, the Keratotest, was developed with 10 laser-engraved mosaics and different predetermined "cell" densities re...
متن کاملFrequency of Causes of Corneal Re-graft during 5 Years at Khalili Hospital, Shiraz
Purpose: To evaluate study of corneal the frequency of re-graft during 5 years at Khalili hospital, Shiraz. Methods: In this retrospective observational study, all corneal re-grafts during 5 years (2009-2014) were assessed at Khalili Hospital, Shiraz. Demographic data of 76 cases, out of total of 1 190 transplants, were retrieved, including age, area of residence, primary disease, type of graft...
متن کاملCLINICAL SCIENCE Value of two mortality assessment techniques for organ cultured corneal endothelium: trypan blue versus TUNEL technique
Background/aim: It is known that trypan blue staining is not a good predictor of loss of corneal endothelial cells (ECs) during organ culture. As it is primarily an indicator of membrane integrity, it would also not be expected to identify ECs undergoing apoptosis. The aim of this study was to determine the ability of the in situ TdT dUTP mediated nick end labelling (TUNEL) technique to detect ...
متن کاملComparison of Three Instructional Methods for Drug Calculation Skill in Nursing Critical Care Courses: Lecturing, Problem Solving, and Computer-Assisted Self-Learning
Introduction: Due to development of educational systems and importance of education in the nursing profession, the necessity of using appropriate instructional methods for new theoretical and practical skills in students is clear. The purpose of this study is comparing the effects of three methods lecture, problem solving, and computer-assisted self learning on the drug calculation skill on thi...
متن کاملValue of two mortality assessment techniques for organ cultured corneal endothelium: trypan blue versus TUNEL technique.
BACKGROUND/AIM It is known that trypan blue staining is not a good predictor of loss of corneal endothelial cells (ECs) during organ culture. As it is primarily an indicator of membrane integrity, it would also not be expected to identify ECs undergoing apoptosis. The aim of this study was to determine the ability of the in situ TdT dUTP mediated nick end labelling (TUNEL) technique to detect c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 48 5 شماره
صفحات -
تاریخ انتشار 2007