Flow Condensation of Pure and Oil Contaminated Refrigerant HFC134a in a Horizontal Tube

نویسندگان

  • W. Shao
  • Wei Shao
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Experimental Comparison of Evaporation and Condensation Heat Transfer Coefficients for HFC-134a and CFC-12

Evaporation of HFC134a inside smooth, horizontal tubes is studied. Te,;ts are made with pure refngerant and with oil-refrigerant mixtures. Heat flux has varied from 2 kW/n? to 10 kW/m . The inner diameter of the tubes are 12 mm. T1.1o evaporators are used, 4 and 10 m long. Oil content is varied from 0 to 2.5 mass percentage (synthetic oil, EXP-0275). Oil free HFC134a is found to have higher hea...

متن کامل

Experimental Study on the Heat Transfer Performance of a Zeotropic Refrigerant Mixture in Horizontal Tubes

In the present study, the condensation and evaporation heat transfer performance of a zeotropic refrigerant mixture (HFC32/HFC125/HFC134a) inside horizontal tubes with smooth, grooved or cross·grooved inner surfaces was investigated experimentally. The cross-gTOoved tube showed the highest heat transfer coefficient for both condensation and evaporation with the zeotropic mixture. Its heat trans...

متن کامل

Heat Transfer Coefficient, Two-Phase Flow Boiling of HFC134a

Experimental measurements of local heat tra nsfer coefficients and pressure drop are made for forced conv ection boiling and condensation for R134a-oil mixtures inside a horizontal tube. The results are compared with the experime ntal data of pure Rl34a. Average convection boiling and cond ensation heat transfer coefficients decreased about 20% at a 10\ o il mass fraction, and boiling and conde...

متن کامل

Condensation Heat Transfer Coefficients of HFC245fa on a Horizontal Plain Tube

In this study, condensation heat transfer coefficients (HTCs) of HCFC22, HCFC123, HFC134a and HFC245fa are measured on a horizontal plain tube 19.0 mm outside diameter. All data are taken at the vapor temperature of 39 with a wall subcooling temperature 3-8 . Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, HFC245fa, on a smooth tube are 9.5% higher than...

متن کامل

Enhancement Effect of a Microfin Tube in Condensation of R407C

In the present paper the heat exchange performance of a counter flow double-tube condenser for a ternary refrigerant mixture R407C, composed ofHFC32/HFC125/HFC134a, is calculated using a prediction method developed by the present authors. The axial distributions of vapor and liquid bulk mass fraction, temperature, heat flux, mass flux, etc., are obtained for both a smooth tube and a microfin tu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014