Leadless cardiac pacing

نویسنده

  • Arun Gopi
چکیده

Transvenous cardiac pacemakers definitely improve quality of life and reduce mortality in at-risk patients, but they are associated with several potential device-related complications. Approximately 10% of patients experience complications related to transvenous implantation of the pacemaker. These may be attributable to either the pulse generator (hematoma, skin breakdown, pocket infection) or venous access and lead implantation (pneumothorax, cardiac tamponade, lead dislodgement) [1]. Pacemaker leads continue to be the “Achilles' heel” of the pacing and defibrillation systems. In the long term, transvenous leads, often considered theweakest link of the cardiac pacing system, can cause venous obstruction and are prone to insulation breaks, conductor fractures, and infections [1e3].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in Pacing and Defibrillation

Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ...

متن کامل

Retrieval of the Leadless Cardiac Pacemaker

Leadless cardiac pacemakers (LPs) have emerged as a safe and effective alternative to conventional transvenous pacemakers for patients with an indication for single-chamber ventricular pacing. In 2 prospective studies with intermediate follow-up, leadless pacemakers exhibited high acute implantation success rates and stable pacing performance at 6 months. Despite these promising results, the ab...

متن کامل

State of the art of leadless pacing.

Despite undisputable benefits, conventional pacemaker therapy is associated with specific complications related to the subcutaneous device and the transvenous leads. Recently, two miniaturized leadless pacemakers, Nanostim™ (St. Jude Medical) and Micra™ (Medtronic), which can be completely implanted inside the right ventricle using steerable delivery systems, entered clinical application. The W...

متن کامل

ECGs and Pacemakers

Leadless pacemakers will most likely be the future of cardiac pacing. Leadless pacing employs a singlechamber system to pace only the right ventricle and is fully self-contained, which eliminates the need for leads. These systems, implanted by using a transcatheter sheath, are indicated for patients who need right ventricular pacing only. These devices enable patients to avoid lead-related comp...

متن کامل

Feasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles

A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-inj...

متن کامل

Permanent leadless cardiac pacing: results of the LEADLESS trial.

BACKGROUND Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. METHODS AND RESULTS The primary safety end point was freedom from complications at 90 days. Sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016