Relation between outer and luminal diameter in cannulated arteries.

نویسندگان

  • Gilles Faury
  • Gail M Maher
  • Dean Y Li
  • Mark T Keating
  • Robert P Mecham
  • Walter A Boyle
چکیده

Resistance in blood vessels is directly related to the inner (luminal) diameter (ID). However, ID can be difficult to measure during physiological experiments because of poor transillumination of thick-walled or tightly constricted vessels. We investigated whether the wall cross-sectional area (WCSA) in cannulated arteries is nearly constant, allowing IDs to be calculated from outer diameters (OD) using a single determination of WCSA. With the use of image analysis, OD and ID were directly measured using either transillumination or a fluorescent marker in the lumen. IDs from a variety of vessel types were calculated from WCSA at several reference pressures. Calculated IDs at all of the reference WCSA were within 5% (mean <1%) of the corresponding measured IDs in all vessel types studied, including vessels from heterozygote elastin knockout animals. This was true over a wide range of transmural pressures, during treatment with agonists, and before and after treatment with KCN. In conclusion, WCSA remains virtually constant in cannulated vessels, allowing accurate determination of ID from OD measurement under a variety of experimental conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Histomorphometric study of brachiocephalic artery of Japanese quail

Brachiocephalic arteries in quails are large arteries which are arising separately from the aortic arch. The aim of the present study was to determine the histomorphometric aspects of brachiocephalic arteries in the Japanese quail. The different layers of the brachiocephalic artery were studied quantitatively in 10, 20 and 60 days-old Japanese quail; (n = 6) and both sexes. Luminal diameter, th...

متن کامل

Electrical stimulation of the endothelial surface of pressurized cat middle cerebral artery results in TTX-sensitive vasoconstriction.

The purpose of this study was to examine the electrical and mechanical responses of cat middle cerebral arteries to electrical stimulation of the adventitial vs. intimal surface of the vessels and to determine the responses as a function of transmural pressure. Middle cerebral arteries were cannulated at both ends. Within each cannula was a stimulating electrode. Electrical stimulation (0.5-mse...

متن کامل

Flow inhibits inward remodeling in cannulated porcine small coronary arteries.

The mechanisms of flow-induced vascular remodeling are poorly understood, especially in the coronary microcirculation. We hypothesized that application of flow in small coronary arteries in organoid culture would cause a nitric oxide (NO)-mediated dilation and inhibit inward remodeling. We developed an organoid culture setup to drive a flow through cannulated arterioles at constant luminal pres...

متن کامل

Effects of overweight on luminal diameter, flow velocity and intima-media thickness of carotid arteries.

PURPOSE To the best of our knowledge, there are only a few previous studies on the effects of overweight on extracranial carotid arteries. We aimed to investigate the effects of overweight on flow velocities, luminal diameters and intima media thicknesses (IMTs) of the common and internal carotid arteries (CCA, ICA). MATERIALS AND METHODS A prospective study on color duplex sonography of the ...

متن کامل

Recoil following Wiktor stent implantation for restenotic lesions of coronary arteries.

The purpose of this study was to determine acute recoil of the vessel wall immediately after Wiktor stent implantation in native coronary arteries of 77 consecutive patients and to assess whether there was compression or "late recoil" of the stent itself at long-term follow-up. Furthermore, the relationship between recoil and a number of clinical, angiographic, and procedural variables was stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 277 5  شماره 

صفحات  -

تاریخ انتشار 1999