Predicted and Measured Creatinine Clearance for the Estimation of Renal Graft Function: New Tools from Body Composition Analysis

نویسنده

  • Carlo Donadio
چکیده

Aim of this study was to evaluate, in Renal Transplant Recipients (RTR), a new method to predict Creatinine Clearance (Ccr) from Plasma Creatinine (Pcr) and from the value of Body Cell Mass (BCM). The values of BCM were obtained, from body impedance analysis (BIA) using an impedance plethysmograph, in 87 RTR with different graft function. The ratios of 24-hour Urinary Creatinine Excretion (Ucr) over BCM were calculated in 30 RTR. In the remaining 57 RTR, Ccr was predicted from Pcr and individual values of BCM (BCM Ccr), using the mean ratio Ucr/BCM found in the first group of patients. In the same patients, Ccr was predicted according to Cockcroft and Gault (CG Ccr). The mean of triplicate measurement of 24-hour Ccr (24 h Ccr), obtained by the standard formula Ucr x Vol/min/Pcr, was used as the reference value of renal graft function. BCM Ccr had a better agreement with 24 h Ccr than CG Ccr, particularly in patients with graft failure. Thanks to its simplicity, accuracy and reproducibility, BCM Ccr is more suitable than 24-hour Ccr to estimate graft function. In the meantime, the body composition data gives useful information for the evalutation of nutritional status and of the equilibrium of body fluid compartments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Body Composition Analysis Allows the Prediction of Urinary Creatinine Excretion and of Renal Function in Chronic Kidney Disease Patients

The aim of this study was to predict urinary creatinine excretion (UCr), creatinine clearance (CCr) and the glomerular filtration rate (GFR) from body composition analysis. Body cell mass (BCM) is the compartment which contains muscle mass, which is where creatinine is generated. BCM was measured with body impedance analysis in 165 chronic kidney disease (CKD) adult patients (72 women) with ser...

متن کامل

بررسی مقایسه‌ای ارزش تشخیصی سیستاتین C و کراتینین سرمی در ارزیابی عملکرد کلیه پیوندی در بیماران گیرنده کلیه در دوران اولیه پس از پیوند

   Background &Aim: Early detection of decreasing glomerular filtration rate (GFR) is critical to prevent graft rejection in post-transplantation period. Serum creatinine has several drawbacks as a marker of GFR, so serum cystatin C has been proposed as an alternative GFR marker. Thus, we prospectively evaluated the diagnostic value of cystatin C measurements compared with serum creatinine in t...

متن کامل

Long term effects of kidney donation on blood pressure and kidney function of donors

Introduction: Kidney transplantation from a live donor has many advantages, but the donor should undergo a major surgery and accept potential morbidity and mortality. In this study, we evaluated the long term effects of nephrectomy on renal function and blood pressure of kidney donors. Methods: In this cross-sectional study, we assessed 195 kidney donors. The controls were 100 healthy individu...

متن کامل

SERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)

Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...

متن کامل

Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure.

AIM To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. METHODS Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simulta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014