Forced expiratory time--its reliability as a lung function test.

نویسندگان

  • J B Macdonald
  • T J Cole
  • A Seaton
چکیده

Three studies of factors affecting variability of forced expiratory time (FET) have been carried out. In the first, different observers or repeated measurements over a few minutes were shown to make no significant contribution to FET variability. Time of day was also relatively unimportant. In the second study, FET was shown to vary considerably more than peak flow rate, forced expiratory volumes, and mid expiratory flow rates over the course of five days. In the third study, FET was shown to correlate with other measurements of airways obstruction though the correlation coefficients were relatively low. The measurement of FET is thought to be too variable to be of practical use as a screening test for small airways disease, though its clinical value is not questioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test

Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...

متن کامل

Reduced Lung Function and Progression to Prediabetes: A Prospective Study

Objective: Prediabetes is a state that people have blood glucose levels higher than normal but still not in diabetes range. There is a close relationship between impaired lung function and diabetes mellitus (DM). Reduced lung function can be present before the clinical evidence of diabetes or insulin resistance. Materials and Methods: The total number of subjects in this longitudinal study was ...

متن کامل

Relationship of lung function loss to level of initial function: correcting for measurement error using the reliability coefficient.

The regression of lung function change on the initial lung function level is biased when the initial level is measured with random error. Several methods have been proposed to obtain unbiased estimates of regression coefficients in such circumstances. We apply these methods to examine the relationship between lung function loss over 11 years and its initial level in 433 men aged about 20 when f...

متن کامل

Effects of Sodium Cromoglycate on Iranian Asthmatic Subjects Without Exposure to any Bronchoconstrictor agent

   Cromolyn sodium, a mast cell stabilizing agent, provides an immediate protective effect against the exercise-induced bronchoconstriction while being used before the exercise. However, cromolyn is ineffective in reversing asthmatic bronchospasm; it is used as a maintenance therapy and has a prophylactic role in chronic asthma.    The purpose of this study was to determine the extent of change...

متن کامل

Effects of Sodium Cromoglycate on Iranian Asthmatic Subjects Without Exposure to any Bronchoconstrictor agent

   Cromolyn sodium, a mast cell stabilizing agent, provides an immediate protective effect against the exercise-induced bronchoconstriction while being used before the exercise. However, cromolyn is ineffective in reversing asthmatic bronchospasm; it is used as a maintenance therapy and has a prophylactic role in chronic asthma.    The purpose of this study was to determine the extent of change...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 1975