Performance of hollow-fiber flow field-flow fractionation in protein separation.

نویسندگان

  • Ilyong Park
  • Ki-Jung Paeng
  • Dukjin Kang
  • Myeong Hee Moon
چکیده

Since hollow-fiber flow field-flow fractionation (HF FIFFF) utilizes a cylindrical channel made of a hollow-fiber membrane, which is inexpensive and simple in channel assembly and thus disposable, interests are increasing as a potential separation device in cells, proteins, and macromolecules. In this study, performance of HF FIFFF of proteins is described by examining the influence of flow rate conditions and length of fiber (polyacrylonitrile or PAN in this work) on sample recovery as well as experimental plate heights. The interfiber reproducibility in terms of separation time and recovery was also studied. Experiments showed that sample recovery was consistent regardless of the length of fiber when the effective field strength (equivalent to the mean flow velocity at the fiber wall) and the channel void time were adjusted to be equivalent for channels of various fiber lengths. This supported that the majority of sample loss in HF FIFFF separation of apoferritin and their aggregates may occur before the migration process. It is finally demonstrated that HF FIFFF can be applied for characterizing the reduction in Stokes' size of low density lipoproteins from blood plasma samples obtained from patients having coronary artery disease and from healthy donors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hollow fiber flow field-flow fractionation of proteins using a microbore channel.

Protein separation through hollow fiber flow field-flow fractionation (HF FlFFF) at microflow rate regime was successfully achieved by employing a microbore hollow fiber. In most of the flow field-flow fractionation (FlFFF) techniques applied to the separation of proteins, including hollow fiber FlFFF (HF FlFFF), an outflow rate leading to a detector has typically been a few tenths of a millili...

متن کامل

Evaluation of multiplexed hollow fiber flow field-flow fractionation for semi-preparative purposes.

A multiplexed hollow fiber flow field-flow fractionation (MxHF5) is introduced to increase throughput of an HF5 channel system for semi-preparative purposes. HF5, a cylindrical version of the flow field-flow fractionation (FlFFF) operated with a porous, hollow fiber membrane by controlling the ratio of radial and axial flow rates, is capable of fractionating proteins, cells, and macromolecules ...

متن کامل

Development of non-gel-based two-dimensional separation of intact proteins by an on-line hyphenation of capillary isoelectric focusing and hollow fiber flow field-flow fractionation.

A rapid, non-gel-based, on-line, two-dimensional separation method is introduced for proteome analysis. Protein fractionation was carried out by first exploiting the differences in their respective isoelectric points (pI) in a Teflon capillary using isoelectric focusing (IEF), followed by a molecular weight (MW)-based separation in a hollow fiber by flow field-flow fractionation (FlFFF). The me...

متن کامل

Lanthanide phosphate nanorods as inorganic fluorescent labels in cell biology research.

density lipoproteins in normal humans. J Lipid Res 1982;23:97–104. 6. Scheffer PG, Bakker SJL, Heine RJ, Teerlink T. Measurement of LDL particle size in whole plasma and serum by high-performance gel-filtration chromatography using a fluorescent lipid probe. Clin Chem 1998;44:2148–51. 7. Teerlink T, Scheffer PG, Bakker SJL, Heine RJ. Combined data from LDL composition and size measurement are c...

متن کامل

Effect of sodium dodecyl sulfate on protein separation by hollow fiber flow field-flow fractionation.

Effects of protein denaturation and formation of protein-sodium dodecyl sulfate (SDS) complexes on protein separation and identification were investigated using hollow fiber flow field-flow fractionation (HF5) and nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Denaturation and formation of protein-SDS complexes prior to HF5 separation resulted a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of separation science

دوره 28 16  شماره 

صفحات  -

تاریخ انتشار 2005