Performance of exhaust-protective (class I) biological 'safety' cabinets.
نویسنده
چکیده
Nineteen open-fronted (class I) safety cabinets were subjected to spore containment and airflow tests, which suggested that a flow of 0.75 m/s was the minimum required for safe operation; further tests on three of the cabinets were repeated at different air speeds and confirmed this. The airflow is required to overcome the effect of laboratory or external air currents. Contamination of surfaces (including the operator's hands) by aerosols liberated inside the cabinets was investigated and found to depend more on turbulence within the cabinet (as from a restricted front opening) than on the number of air changes. The findings suggest that the product protection provided by a well-designed class I cabinet might equal that of a class II (laminar flow) unit.
منابع مشابه
HEPA EXHAUST FILTER IV HEPA SUPPLY FILTER I / All
A microbiological survey of the effectiveness of class II (laminar flow) 'safety' cabinets found in the UK in the last six years is recorded. Only two of the nine units tested approached the containment of aerosols achieved by a good class I (exhaust protective) cabinet. The others were potentially hazardous if used with pathogenic material. The National Sanitation Foundation and the British St...
متن کاملMeasuring the Loss of Dexterity during Microbiological Containment Systems Use
Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...
متن کاملMeasuring the Loss of Dexterity during Microbiological
Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...
متن کاملSafety of portable inoculation cabinets.
Laboratory work with pathogenic microorganisms should be performed in a ventilated safety cabinet. A minimum airflow of 0-5 metres per second through the working aperture has been recommended, with discharge of the exhaust air through a filter, then into the open air (Department of Health and Social Security, 1970). Such a unit must be permanently installed. There are possible advantages to a p...
متن کاملارزیابی عملکرد هودهای بیولوژِیکی ایمن در یک مرکز تحقیقاتی
The use of biological safety cabinets (BSCs) in laboratories has greatly increased over the last few decades. BSCs are used in laboratories to protect both the scientists and the experiments from contamination by biological hazards during tissue culture procedures. The function of BSCs depends upon the HEPA filtration, the fan performance and the airflow patterns in the cabinet. To ensure BSCs ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 32 6 شماره
صفحات -
تاریخ انتشار 1979