Validation of a blood plasma separation system by biomarker detection.
نویسندگان
چکیده
A microfluidic system was developed for blood plasma separation at high flow rate. This system uses only hydrodynamic forces to separate plasma from whole blood. The microfluidic network features a series of constrictions and bifurcations to enhance the product yield and purity. A maximum purity efficiency of 100% is obtained on blood with entrance hematocrit level up to 30% with a flow rate of 2 mL h(-1). Flow cytometry was performed on the extracted plasma to evaluate the separation efficiency and to assess cell damage. A core target of this study was the detection of cell-free DNA from the on-chip extracted plasma. To this effect, PCR was successfully carried out off-chip on the cell-free DNA present in the plasma extracted on-chip. A house-keeping gene sequence (GAPDH) was amplified without the need for a purification after the separation, thereby showing the high quality of the plasma sample. The resulting data suggests that the system can be used as a preliminary module of a total analysis system for cell-free DNA detection in human plasma.
منابع مشابه
Method validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملParkinson’s Disease-related Circulating microRNA Biomarkers –– a Validation Study
Parkinson’s disease (PD) is the second most common neurodegenerative disease. One of the major challenges in studying this progressive neurological disorder is to identify and develop biomarkers for early detection. Recently, several blood-based microRNA (miRNA) biomarkers for PD have been reported. However, follow-up studies with new, independent cohorts have been rare. Previously, we identifi...
متن کاملHuman plasma derived drugs separation by fractionation of plasma with polyethylene glycol
Background: There are varieties of purification techniques for separation of human plasma proteins such as salting out, ion exchange chromatography, and ethanol fractionation. There are limitations for each method, for example in salting out method, the salt has to be removed in an additional step. Ion exchange chromatography is difficult for scaling up, and plasma fractionation is a time consu...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Lab on a chip
دوره 10 12 شماره
صفحات -
تاریخ انتشار 2010