Mechanical testing of a device for subcutaneous internal anterior pelvic ring fixation versus external pelvic ring fixation

نویسندگان

  • Georg Osterhoff
  • Simon Tiziani
  • Stephen J Ferguson
  • Gregor Spreiter
  • Max J Scheyerer
  • Gian-Leza Spinas
  • Guido A Wanner
  • Hans-Peter Simmen
  • Clément ML Werner
چکیده

BACKGROUND Although useful in the emergency treatment of pelvic ring injuries, external fixation is associated with pin tract infections, the patient's limited mobility and a restricted surgical accessibility to the lower abdomen. In this study, the mechanical stability of a subcutaneous internal anterior fixation (SIAF) system is investigated. METHODS A standard external fixation and a SIAF system were tested on pairs of Polyoxymethylene testing cylinders using a universal testing machine. Each specimen was subjected to a total of 2000 consecutive cyclic loadings at 1 Hz with sinusoidal lateral compression/distraction (+/-50 N) and torque (+/- 0.5 Nm) loading alternating every 200 cycles. Translational and rotational stiffness were determined at 100, 300, 500, 700 and 900 cycles. RESULTS There was no significant difference in translational stiffness between the SIAF and the standard external fixation when compared at 500 (p = .089), 700 (p = .081), and 900 (p = .266) cycles. Rotational stiffness observed for the SIAF was about 50 percent higher than the standard external fixation at 300 (p = .005), 500 (p = .020), and 900 (p = .005) cycles. No loosening or failure of the rod-pin/rod-screw interfaces was seen. CONCLUSIONS In comparison with the standard external fixation system, the tested device for subcutaneous internal anterior fixation (SIAF) in vitro has similar translational and superior rotational stiffness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Modified pedicle screw-rod fixation versus anterior pelvic external fixation for the management of anterior pelvic ring fractures: a comparative study

BACKGROUND Anterior pelvic ring fracture, as high-energy trauma, needs to be effectively treated. The purpose of the current study was to evaluate the clinical applications of modified pedicle screw-rod fixation and anterior pelvic external fixation for the treatment of anterior pelvic ring fracture. METHODS Either modified pedicle screw-rod fixation (modified PSRF group, N = 21) or anterior ...

متن کامل

Treatment of unstable pelvic ring injuries with an internal anterior fixator: initial clinical series

Objective: To investigate the clinical effectiveness of minimally invasive subcutaneous pedicle screw and rod system in treatment of anterior pelvic ring injury. Methods: Altogether, 28 patients (17 men, 11 women; average age 39.8 years, range 19-68 years) with pelvic ring fractures were treated using a subcutaneous internal anterior fixation device composed of supra-acetabular spinal pedicle s...

متن کامل

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

The value of external fixation for unstable pelvic ring injuries.

Unstable pelvic ring injuries are severe injuries, with high morbidity and mortality rates. Since 1994, the authors have been using external fixation to treat these injuries. They present the results achieved in a series of 22 cases of unstable pelvic ring injuries admitted to their institution between 1994 and 2001. External fixation was performed in all cases with pins inserted between the an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014