Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide fick method.
نویسندگان
چکیده
BACKGROUND It remains a great challenge to measure systemic blood flow in critically ill newborns. In a former study we validated the modified carbon dioxide Fick (mCO(2)F) method for measurement of cardiac output in a newborn lamb model. In this new study we studied the influence of a left-to-right shunt on the accuracy of the mCO(2)F method. OBJECTIVE To analyze the influence of a left-to-right shunt on the agreement between cardiac output measurement with the mCO(2)F method and ultrasonic transit time pulmonary blood flow in a lamb model. METHODS The study was approved by the Ethical Committee on Animal Research of the Radboud University Nijmegen and performed in 8 random-bred lambs. A Gore-Tex shunt was placed between the left pulmonary artery and the descending aorta. This aortopulmonary shunt was intermittently opened and closed, while cardiac output was manipulated by creating hemorrhagic hypotension. Cardiac output measurement with the mCO(2)F method (Q(mCO2F)) was compared with pulmonary blood flow obtained by a transit time ultrasonic flow probe positioned around the common pulmonary artery (Q(APC)). RESULTS Bias, defined as Q(mCO2F) - Q(APC), was calculated for each measurement. With an open shunt there was a significant left-to-right shunt (mean Qp/Qs ratio 2.26; range 1.56-3.69). Mean bias (SD) was -12.3 (50.4) ml x kg(-1) x min(-1) and -12.3 (42.7) ml x kg(-1) x min(-1) for measurements with a closed and open shunt, respectively (no statistical significant difference). CONCLUSIONS Cardiac output measurement with the mCO(2)F method is reliable and easily applicable in ventilated newborn lambs, also in the presence of a significant left-to-right shunt.
منابع مشابه
Cardiac output measurement using a modified carbon dioxide Fick method: comparison analysis with pulmonary artery catheter method and pulse induced contour cardiac output method.
OBJECTIVES In the present study, cardiac output in mechanically ventilated patients were determined using three methods including modified CO2-Fick (mCO2F), pulmonary artery catheter (PAC), and pulse induced contour cardiac output (PiCCO) methods and the results were compared to assess the effectiveness of mCO2F method in measuring the cardiac output. METHOD Mechanically ventilated and hemody...
متن کاملComparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients
INTRODUCTION Bedside cardiac output determination is a common preoccupation in the critically ill. All available methods have drawbacks. We wished to re-examine the agreement between cardiac output determined using the thermodilution method (QTTHERM) and cardiac output determined using the metabolic (Fick) method (QTFICK) in patients with extremely severe states, all the more so in the context ...
متن کاملNon-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.
Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of ...
متن کاملComparison of cardiac output determined by a carbon dioxide-rebreathing and direct Fick method at rest and during exercise.
1. To study the validity of a CO2-rebreathing method at rest and during graded exercise, cardiac output was measured simultaneously on 59 occasions in 16 subjects with normal pulmonary function with the CO2-rebreathing method and the direct Fick method for oxygen. The correlation coefficient between the results of both methods was significantly higher during exercise than at rest. 2. No systema...
متن کاملEffects of altered patterns of ventilation and of increased cardiac output on blood flow to a collapsed lung in anaesthetized, closed-chest dogs.
Right-to-left shunt (Qs/Qt) was measured by the SF6 and oxygen methods in 13 anaesthetized closed-chest dogs intubated with a double-lumen endobronchial tube. Collapse of the left lung increased Qs/Qt from 10% to 23%, suggesting that blood flow to the left lung had been reduced by about 60%. Increasing right lung mean airway pressure by the alteration of the inspiratory:expiratory time ratio or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neonatology
دوره 97 2 شماره
صفحات -
تاریخ انتشار 2010