Intimal hyperplasia following implantation of helical-centreline and straight-centreline stents in common carotid arteries in healthy pigs: influence of intraluminal flow.
نویسندگان
چکیده
Intimal hyperplasia (IH) is a leading cause of obstruction of vascular interventions, including arterial stents, bypass grafts and arteriovenous grafts and fistulae. Proposals to account for arterial stent-associated IH include wall damage, low wall shear stress (WSS), disturbed flow and, although not widely recognized, wall hypoxia. The common non-planarity of arterial geometry and flow, led us to develop a bare-metal, nitinol, self-expanding stent with three-dimensional helical-centreline geometry. This was deployed in one common carotid artery of healthy pigs, with a straight-centreline, but otherwise identical (conventional) stent deployed contralaterally. Both stent types deformed the arteries, but the helical-centreline device additionally deformed them helically and caused swirling of intraluminal flow. At sacrifice, one month post stent deployment, histology revealed significantly less IH in the helical-centreline than straight-centreline stented vessels. Medial cross-sectional area was not significantly different in helical-centreline than straight-centreline stented vessels. By contrast, luminal cross-sectional area was significantly larger in helical-centreline than straight-centreline stented vessels. Mechanisms considered to account for those results include enhanced intraluminal WSS and enhanced intraluminal blood-vessel wall mass transport, including of oxygen, in the helical-centreline stented vessels. Consistent with the latter proposal, adventitial microvessel density was lower in the helical-centreline stented than straight-centreline stented vessels.
منابع مشابه
Carotid stenting using heparin-coated balloon-expandable stent reduces intimal hyperplasia in a baboon model.
PURPOSE This study evaluates the effect of heparin-coated balloon-expandable stents on intimal hyperplasia following carotid artery stenting in a baboon model. MATERIALS AND METHODS Balloon-expandable (Palmaz-Schatz) stents were placed in bilateral common carotid arteries in 26 male baboons (mean weight: 11.3 kg). In each animal, a heparin-coated (HC) carotid stent was placed on one side, whe...
متن کاملMorphometric analysis of intimal thickening secondary to stent placement in pig carotid arteries Análise morfométrica do espessamento intimal secundário ao implante de stent em artérias carótidas de suínos
Objective: To evaluate intimal thickening secondary to stent placement or to insertion of the delivery system without stent placement in pig carotid arteries. Methods: Stents were placed in the right common carotid arteries of 7 pigs, and 7 other control pigs underwent only insertion of the delivery system without stent placement. Uninjured contralateral common carotid arteries of the two group...
متن کاملStent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.
AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...
متن کاملSelf-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.
PURPOSE To assess the efficacy of metal stents for the treatment of different forms and sizes of carotid aneurysms. METHODS A total of 14 experimentally constructed aneurysms in dogs were treated with transfemorally placed balloon-expandable tantalum and self-expanding nitinol stents. RESULTS In 10 cases, stenting produced either immediate complete occlusion of the aneurysm (n = 7) or compl...
متن کاملSirolimus-eluting stents to abolish intimal hyperplasia and improve flow in porcine arteriovenous grafts: a 4-week follow-up study.
BACKGROUND The patency of arteriovenous (AV) expanded polytetrafluoroethylene (ePTFE) hemodialysis grafts is severely compromised by intimal hyperplasia (IH) at the venous anastomosis and in the venous outflow tract. We addressed the potential of primary placement of a sirolimus-eluting stent (SES) in a validated porcine model. METHODS AND RESULTS In 25 pigs, ePTFE AV grafts were created bila...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Royal Society, Interface
دوره 10 89 شماره
صفحات -
تاریخ انتشار 2013