Robotic voltammetry with carbon nanotube-based sensors: a superb blend for convenient high-quality antimicrobial trace analysis
نویسندگان
چکیده
A new automated pharmacoanalytical technique for convenient quantification of redox-active antibiotics has been established by combining the benefits of a carbon nanotube (CNT) sensor modification with electrocatalytic activity for analyte detection with the merits of a robotic electrochemical device that is capable of sequential nonmanual sample measurements in 24-well microtiter plates. Norfloxacin (NFX) and ciprofloxacin (CFX), two standard fluoroquinolone antibiotics, were used in automated calibration measurements by differential pulse voltammetry (DPV) and accomplished were linear ranges of 1-10 μM and 2-100 μM for NFX and CFX, respectively. The lowest detectable levels were estimated to be 0.3±0.1 μM (n=7) for NFX and 1.6±0.1 μM (n=7) for CFX. In standard solutions or tablet samples of known content, both analytes could be quantified with the robotic DPV microtiter plate assay, with recoveries within ±4% of 100%. And recoveries were as good when NFX was evaluated in human serum samples with added NFX. The use of simple instrumentation, convenience in execution, and high effectiveness in analyte quantitation suggest the merger between automated microtiter plate voltammetry and CNT-supported electrochemical drug detection as a novel methodology for antibiotic testing in pharmaceutical and clinical research and quality control laboratories.
منابع مشابه
A Sensitive Novel Approach towards the Detection of 8-Hydroxyquinoline at Anionic Surfactant Modified Carbon Nanotube Based Biosensor: A Voltammetric Study
A rapid electrochemical technique was developed to determine 8-Hydroxyquinoline (8HQ). In the current study, the anionic surfactant Sodium lauryl sulfate (SLS) was immobilized on the multi-walled carbon nanotube (MWCNT) paste surface for the fabrication of electrode to detect 8HQ in phosphate buffer solution (PBS) of pH 7.0. The response of SLS modified carbon nanotube paste electrode (SLSMCNTP...
متن کاملAn efficient platform based on cupper complex-multiwalled carbon nanotube nanocomposite modified electrode for the determination of uric acid
A new voltammetric sensor for determination of uric acid (UA) by Cuppercomplex- multiwalled carbon nanotube (Cu-complex-CNT) nanocomposite modifiedcarbon paste electrode (CPE) is reported. The electrocatalytic behavior of theCu-complex-CNT nanocomposite modified CPE was studied in pH 2.0 phosphatebuffer solution by chronoamperometry (CA) and cyclic voltammetry (CV) in th...
متن کاملElectrochemical Determination of Trace Sudan I Contamination in Chili Powder at Carbon Nanotube Modified Electrodes
We have developed a simple, convenient and inexpensive voltammetric method for determining trace Sudan I contamination in chili powder, based on the catalyzed electrochemical reduction of Sudan I at the carbon nanotube modified electrode. Under optimized conditions, the method exhibited acceptable analytical performance in terms of linearity (over the concentration range 6.0×10-7 to 7.5×10-5 M,...
متن کاملA Certain Electrochemical Nanosensor Based on Functionalized Multi-Walled Carbon Nanotube for Determination of Cysteine in the Presence of Paracetamol
The modified glassy carbon electrode (GCE) was prepared with 6-amino-4-(3,4-dihydroxyphenyl)-3-methyl-1,4-dihydropyrano[2,3-c]pyrazole-5-carbonitrile (pyrazole derivative (AMPC)) and functionalized multi-walled carbon nanotubes. In this research, electrocatalytic activity of nanocomposite (AMPC/MWCNTs) has been studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoa...
متن کاملApplication of CuO nano particle/multi-walled carbon nanotube nanocomposite modified electrode for simultaneous determination of dopamine and rutin in real samples
Background: In this work, a new method was developed for simultaneous determination of dopamine and rutin at glassy carbon electrode modified with CuO nanoparticles doped multi-walled carbon nanotubes (CuONPs–MWNT/GCE). This modified electrode has shown excellent electrocatalytic activity toward the oxidation of rutin in acetate buffer solution (pH=5). The modified electrode lowered the overpot...
متن کامل