Solar UV-treatment of water samples for stripping-voltammetric determination of trace heavy metals in Awash river, Ethiopia
نویسندگان
چکیده
We report about testing a new mobile and sustainable water sample digestion method in a preliminary field trial in Ethiopia. In order to determine heavy metals at the ultra-trace level by stripping voltammetric techniques in water samples from Awash River, we applied our new method of solar UV-assisted sample pretreatment to destroy the relevant interfering dissolved organic matter. The field tests revealed that 24 h of solar UV irradiation were sufficient to achieve the same sample pretreatment results as with classic digestion method based on intense and hard UV. Analytical results of this study suggest that both a hydroelectric power station and agrichemical applications at Koka Lake have increased the levels of the investigated metals zinc, cadmium, lead, copper, cobalt, nickel, and uranium.
منابع مشابه
Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid
In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...
متن کاملConstruction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...
متن کاملAnodic stripping voltammetry determination of Pb, Cd, Zn, and Cu in blood samples of children in some areas of Ibb governorate
Anodic stripping voltammetric determination of Pb, Cd, Zn and Cu in blood samples of 132 children was developed. The children's ages range was between 6 months and 6 years and the samples were collected from different areas of Ibb governorate (Yemen). We used anodic stripping voltammetry for analyzing and determination of cited metals in the blood of all children. Large variation in the results...
متن کاملDetermination of ultra trace of thiosemicarbazide by adsorptive stripping voltammetric method
In the present work, an adsorptive stripping voltammetric method using a hanging mercurydrop electrode (HMDE) was described in order to determine the ultra trace of thiosemicarbazidein different real samples. The method is based on accumulation of thiosemicarbazide on mercuryelectrode. The potential was scanned to the negative direction and the differential pulse strippingvoltammograms were rec...
متن کاملBismuth/Polyaniline/Glassy Carbon Electrodes Prepared with Different Protocols for Stripping Voltammetric Determination of Trace Cd and Pb in Solutions Having Surfactants
To improve reproducibility, stability and sensitivity, a bismuth (Bi) thin film was coated on glassy carbon (GC) substrates which surfaces were modified with a porous thin layer of polyaniline (PANI) via multipulse potentiostatic electropolymerization to form Bi/PANI/GC electrodes (Bi/PANI/GCEs). The Bi/PANI/GCEs were used successfully for simultaneous detection and determination of Cd2þ and Pb...
متن کامل