Radio Astronomical Polarimetry and High-precision Pulsar Timing
نویسنده
چکیده
A new method of matrix template matching is presented in the context of pulsar timing analysis. Pulse arrival times are typically measured using only the observed total intensity light curve. The new technique exploits the additional timing information available in the polarization of the pulsar signal by modeling the transformation between two polarized light curves in the Fourier domain. For a number of millisecond pulsars, arrival time estimates derived from polarimetric data are predicted to exhibit greater precision and accuracy than those derived from the total intensity alone. Furthermore, the transformation matrix produced during template matching may be used to calibrate observations of other point sources. Subject headings: methods: data analysis — polarization — pulsars: general — techniques: polarimetric
منابع مشابه
Radio Astronomical Polarimetry and Matrix Template Matching
A new method of matrix template matching is presented in the context of pulsar timing analysis. Pulse arrival times are typically measured using only the observed total intensity light curve. The new technique exploits the additional timing information available in the polarization of the pulsar signal by modeling the transformation between two polarized light curves in the Fourier domain. For ...
متن کاملRadio Astronomical Polarimetry and Phase-coherent Matrix Convolution
A new phase-coherent technique for the calibration of polarimetric data is presented. Similar to the one-dimensional form of convolution, data are multiplied by the response function in the frequency domain. Therefore, the system response may be corrected with arbitrarily high spectral resolution, effectively treating the problem of bandwidth depolarization. As well, the original temporal resol...
متن کاملHigh-Precision Timing and Polarimetry of PSR J0437−4715
This thesis reports on the recent results of a continuing, high-precision pulsar timing project, currently focused on the nearby, binary millisecond pulsar, PSR J0437−4715. Pulse arrival time analysis has yielded a remarkable series of constraints on the physical parameters of this system and evidence for the distortion of space-time as predicted by the General Theory of Relativity. Owing to th...
متن کاملRadio Polarization of the Young High-Magnetic-Field Pulsar PSR J1119-6127
We have investigated the radio polarization properties of PSR J1119 6127, a recently discovered young radio pulsar with a large magnetic field. Using pulsar-gated radio imaging data taken at a center frequency of 2496 MHz with the Australia Telescope Compact Array, we have determined a rotation measure for the pulsar of +842 23 rad m 2. These data, combined with archival polarimetry data taken ...
متن کاملRadio Polarization of the Young High–magnetic-field Pulsar
We have investigated the radio polarization properties of PSR J1119-6127, a recently discovered young radio pulsar with a large magnetic field. Using pulsar-gated radio imaging data taken at a center frequency of 2496 MHz with the Australia Telescope Compact Array, we have determined a rotation measure for the -2 pulsar of +842 ± 23 rad m . These data, combined with archival polarimetry data ta...
متن کامل