Clinical Evaluation of an Unsintered Hydroxyapatite/Poly-L-Lactide Osteoconductive Composite Device for the Internal Fixation of Maxillofacial Fractures
نویسندگان
چکیده
INTRODUCTION OSTEOTRANS MX (Takiron Co, Ltd, Osaka, Japan) is a resorbable osteosynthetic material composed of an unsintered hydroxyapatite/poly-L-lactide composite, and its osteoconductive capacity has been documented. The authors here report their clinical experience using OSTEOTRANS MX. METHODS The authors treated 35 patients (19 men, 16 women; age, 14-88 years; mean ± standard deviation, 38.4 ± 19.9 years) with maxillofacial fractures. The authors used standard surgery to stabilize fractures in all patients, fitting resorbable plates (thickness, 1.0 or 1.4 mm) and screws (diameter, 2 mm) according to Arbeitsgemeinschaft für Osteosynthesefragen/Association (AO) for the Study of Internal Fixation guidelines. RESULTS All patients eventually achieved satisfactory healing with favorable restoration of form and function without foreign body reaction. Complications occurred in 3 patients-plate exposure in 2 and discomfort in 1. However, fracture sites healed in all patients. Scanning electron microscopy revealed that the devices bonded directly to the bone without interposition of nonmineralized tissue. CONCLUSION OSTEOTRANS MX is a useful material with few complications. Its osteoconductive bioactivity is advantageous for the early functional improvement of maxillofacial fractures.
منابع مشابه
Biomechanical Loading Evaluation of Unsintered Hydroxyapatite/poly-l-lactide Plate System in Bilateral Sagittal Split Ramus Osteotomy
OSTEOTRANS MX® (Takiron Co., Ltd., Osaka, Japan) is a bioactive resorbable maxillofacial osteosynthetic material composed of an unsintered hydroxyapatite/poly-l-lactide composite, and its effective osteoconductive capacity has been previously documented. However, the mechanical strength of this plate system is unclear. Thus, the aim of this in vitro study was to assess its tensile and shear str...
متن کاملSuccessful Surgical Fixation Using Bio-Absorbable Plates for Frail Chest in a Severe Osteoporotic Octogenarian.
We present a case of a severe osteoporotic octogenarian who sustained serious flail chest from a traffic accident. The 3rd-9th ribs of the right chest wall were fractured. Non-operative management was unsuccessful. We performed a surgical fixation using a bio-absorbable and bio-active mini-plating set. This plating set is unsintered hydroxyapatite (u-HA) particles/poly-L-lactide (PLLA) composit...
متن کاملTreatment of Lateral Tibial Condylar Fractures Using Bioactive, Bioresorbable Forged Composites of Raw Particulate Unsintered Hydroxyapatite/Poly-L-Lactide Screws.
Forged composites of raw particulate unsintered hydroxyapatite/poly-L-lactide (F-u-HA/PLLA) devices possess high mechanical strength, bioactivity, and radio-opacity. The aim of this study was to assess the efficacy of F-u-HA/PLLA screws in the treatment of lateral tibial condylar fractures. From January 2005 to December 2010, a total of 7 patients with displaced closed lateral tibial condylar f...
متن کاملSkeletal stability after mandibular setback surgery: comparisons among unsintered hydroxyapatite/poly-L-lactic acid plate, poly-L-lactic acid plate, and titanium plate.
PURPOSE The purpose of this study is to compare the time-course changes in condylar long-axis and skeletal stability after sagittal split ramus osteotomy (SSRO) with an unsintered hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) plate, PLLA plate, or titanium plate. PATIENTS AND METHODS Of 60 Japanese patients diagnosed with mandibular prognathism, 20 underwent SSRO with a u-HA/PLLA plate syst...
متن کاملMedial Wall Orbital Reconstruction using Unsintered Hydroxyapatite Particles/Poly L-Lactide Composite Implants
BACKGROUND Poly-L-lactide materials combined with hydroxyapatite (u-HA /PLLA) have been developed to overcome the drawbacks of absorbable materials, such as radiolucency and comparably less implant strength. This study was designed to evaluate the usefulness of u-HA/PLLA material in the repair of orbital medial wall defects. METHODS This study included 10 patients with pure medial wall blow-o...
متن کامل