In-house development of an FPGA-based MCA8K for gamma-ray spectrometer

نویسندگان

  • Dang Lanh
  • Pham Ngoc Son
  • Nguyen An Son
چکیده

The objective of this work is domestic development of electronics instruments. It used for measuring ionization radiation and practical training at Nuclear Research Institute (NRI), Dalat, Vietnam. The aim of this work is to study and develop a novel MCA8k for Gamma-ray spectrometer concerning experimental nuclear physics. An approach for design and construction of the aforementioned instrument is to apply logic integrating techniques via Field Programmable Gate Arrays (FPGA) under Max + PlusII, Altera. The instrument allows interfacing to PC with self-developed application software. Scientific significance of this work is partly to contribute to opening a research direction in the field of nuclear electronics science for design and construction of radiation measurement instruments with the advanced IC technology in Vietnam. Practical significance of this work is partly to contribute to enhancement of capabilities in developing radiation measurement instruments for experimental research as well as practical training in nuclear physics. The advantages of FPGA: overcoming ballistic deficit, decrement of serial and parallel noise, flexible in programming, control of the system by software without an interfere of hardware. The disadvantages of FPGA: requirement of good knowledge of VHDL and professional tools for development of a expected project. A new electronics module of MCA8k has been achieved. Some main results obtained from the experimental testing are as follows: differential nonlinearity (DNL) of FPGA-MCA8k approximately 1.27%, integral nonlinearity (INL) = 0.607%, time conversion ≈ 2.2 μs, deadtime (DT) is 0.75%. Data Acquisition Program MCANRI written in VC (+ +)6.0, self-executed under Windows XP environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Development of Low Frequency Pulsed NQR/NMR Spectrometer

An FPGA based NQR spectrometer has been designed for detection of N nuclei. The digital circuits required for NQR spectrometer i.e Pulse Programmer, DDS, digital receiver have been built inside FPGA. Combining FPGA chip with analog components, NQR spectrometer has been developed. N from NaNO2 is observed using same spectrometer. By adding a permanent magnet of uniform field NMR signal of proton...

متن کامل

IMPLEMENTATION OF EXTENDED KALMAN FILTER TO REDUCE NON CYCLO-STATIONARY NOISE IN AERIAL GAMMA RAY SURVEY

Gamma-ray detection has an important role in the enhancement the nuclear safety and provides a proper environment for applications of nuclear radiation. To reduce the risk of exposure, aerial gamma survey is commonly used as an advantage of the distance between the detection system and the radiation sources. One of the most important issues in aerial gamma survey is the detection noise. Various...

متن کامل

Field Programmable Gate Array–based Implementation of an Improved Algorithm for Objects Distance Measurement (TECHNICAL NOTE)

In this work, the design of a low-cost, field programmable gate array (FPGA)-based digital hardware platform that implements image processing algorithms for real-time distance measurement is presented. Using embedded development kit (EDK) tools from Xilinx, the system is developed on a spartan3 / xc3s400, one of the common and low cost field programmable gate arrays from the Xilinx Spartan fami...

متن کامل

Comparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission

Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -