1 A Soft Curtailment of Wide - area Central Air 2 Conditioning Load 3
نویسندگان
چکیده
A real-time two-way direct load control (TWDLC) of central air-conditioning chillers in 10 wide area is proposed to provide demand response. The proposed TWDLC scheme is designed to 11 optimize the load shedding ratio of every customer under control to ensure the target load to be 12 shed is met at every scheduling period. In order to overcome the load reduction uncertainties of 13 TWDLC, an innovative solution is proposed by applying a certain degree of loosening on the 14 constraint of the actual shed load. Fuzzy linear programming is utilized to solve the optimization 15 problem with fuzzy constraints. The proposed fuzzy linear programming problem is solved by 16 delicately transforming it into a regular liner programming problem. A selection scheme used to 17 obtain the feasible candidates set for load shedding at every sampling interval of TWDLC is also 18 designed along with the fuzzy linear programming. 19
منابع مشابه
Evaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran
Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...
متن کاملAdjustable throat-area expansion valves used in automotive air conditioning systems: A mini review
Adjustable throat-area expansion valves (ATAEV) are functioned as area regulator control units. In literatures, there are many expansion valves normally used in automotive air-conditioning systems, as regulator and electrical type valves. Nevertheless, a review study for such issue has not been introduced, according to the best of author knowledge. The present paper presents a review study for ...
متن کاملOptimal Power Flow in the Smart Grid Using Direct Load Control Program
This paper proposes an Optimal Power Flow (OPF) algorithm by Direct Load Control (DLC) programs to optimize the operational cost of smart grids considering various scenarios based on different constraints. The cost function includes active power production cost of available power sources and a novel flexible load curtailment cost associated with DLC programs. The load curtailment cost is based ...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملDetermining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations
One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...