Solid Phase Biosensors for Arsenic or Cadmium Composed of A trans Factor and cis Element Complex

نویسندگان

  • Mohammad Shohel Rana Siddiki
  • Yasunari Kawakami
  • Shunsaku Ueda
  • Isamu Maeda
چکیده

The presence of toxic metals in drinking water has hazardous effects on human health. This study was conducted to develop GFP-based-metal-binding biosensors for on-site assay of toxic metal ions. GFP-tagged ArsR and CadC proteins bound to a cis element, and lost the capability of binding to it in their As- and Cd-binding conformational states, respectively. Water samples containing toxic metals were incubated on a complex of GFP-tagged ArsR or CadC and cis element which was immobilized on a solid surface. Metal concentrations were quantified with fluorescence intensity of the metal-binding states released from the cis element. Fluorescence intensity obtained with the assay significantly increased with increasing concentrations of toxic metals. Detection limits of 1 μg/L for Cd(II) and 5 μg/L for As(III) in purified water and 10 µg/L for Cd(II) and As(III) in tap water and bottled mineral water were achieved by measurement with a battery-powered portable fluorometer after 15-min and 30-min incubation, respectively. A complex of freeze dried GFP-tagged ArsR or CadC binding to cis element was stable at 4 °C and responded to 5 μg/L As(III) or Cd(II). The solid phase biosensors are sensitive, less time-consuming, portable, and could offer a protocol for on-site evaluation of the toxic metals in drinking water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of graphene oxide- magnetic nanoparticle for solid phase extraction of trace amounts of cadmium ions in environmental samples

Abstract In this work, Fe3O4-graphene oxide nanocomposite (GO-Fe3O4) was prepared as effective absorbent for magnetic solid phase extraction (MSPE) of trace quantities of cadmium ions in environmental water and rice samples using 1, 2-dihydroxy anthraquinone-3-sulphonic acid, sodium salt (Alizarin red S) and flame atomic absorption spectrometry (FAAS). The   GO-Fe3O4 was characterized by scanni...

متن کامل

Application of solvent-assisted dispersive solid phase extraction combined with flame atomic absorption spectroscopy for the determination of trace amounts of Cadmium

Introduction: Cadmium is recognized worldwide as a toxic metal. In this study, Solvent-Assisted Dispersive Solid Phase Extraction (SA-DSPE) combined with Flame Atomic Absorption Spectrometry (FAAS), was used for determination of trace amounts of Cadmium (Cd-II)) in drinking water samples. Correspondence: Omid Rahmanian, PhD. ...

متن کامل

Effect of Alkyl Substituents on the Hydrogen Bonding and Molecular Structure of Benzophenylhydroxamic Acids Crystal structure of UO2 Complex of p-Isopropylbenzophenylhydroxamic Acid

The effect of alkyl substituents on the C-phenyl and/or the N-Phenyl ring of benzophenylhydroxamic acid on their molecular structure and hydrogen bonding has been investigated. The predominant configuration in CHCl3 is determined by steric and electronic effects. Substituents on the C-phenyl ring favor the cis configuration, while substituents in the N-phenyl ring favor a trans c...

متن کامل

A New and Efficient Method for the Adsorption and Separation of Arsenic Metal Ion from Mining Waste Waters of Zarshouran Gold Mine by Magnetic Solid-Phase Extraction with Modified Magnetic Nanoparticles

Widespread arsenic contamination of mining wastewater of Zarshouran (West Azerbaijan province) has led to a massive epidemic of arsenic poisoning in the whole of surrounding areas. It is estimated that approximately all agriculture fields are being irrigated with the water that its arsenic concentrations elevated above the World Health Organization’s standard of 10 parts per billion. A novel ad...

متن کامل

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011