CERTIFICATION REPORT The certification of the mass concentration of beta-2-microglobulin in human serum: ERM-DA470k/IFCC
نویسندگان
چکیده
This report describes the additional certification of the mass concentration of beta-2-microglobulin (B2M) in ERM-DA470k/IFCC, a human serum material. The material was released in 2008 and was certified for the mass concentration of 12 proteins in human serum. The material is now additionally certified for B2M in accordance with ISO Guide 34:2009. A full description of the processing steps used to produce the material can be found in the first report. The between unit-homogeneity was quantified and the stability during dispatch and storage were assessed in accordance with ISO Guide 35:2006. The within-unit homogeneity was estimated to determine the minimum sample intake. The material was characterised by an inter-laboratory comparison exercise performed by laboratories of demonstrated competence and with adherence to ISO/IEC 17025. Uncertainties of the certified values were calculated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM) and include uncertainties relating to possible lack of homogeneity, instability and to characterisation. The material is intended for the calibration or control, for the certified proteins only, of immunoassay-based in-vitro diagnostic devices or control products. Any other calibrator should be verified as commutable. The material was produced in a similar manner as ERM-DA470, the use of which has led to a significant reduction in the between-method and between-laboratory variation for the proteins certified (B2M was not certified in this material) [ , ]. It was verified during the value assignment procedure that there were no significant matrix effects, and that different methods produced consistent results. The Certified Reference Material (CRM) is available in the lyophilised form of a 1.0 mL portion of serum with additives (4(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES), sodium azide, benzamidine hydrochloride, sodium chloride and aprotinin). The CRM is available in threaded glass bottles with rubber stoppers and polypropylene screw caps maintained under nitrogen gas. The water mass fraction of the sample is (4.3 ± 0.6) mg/g. The lyophilised powder has to be reconstituted with (1.00 ± 0.01) g of distilled water and the minimum amount of reconstituted sample to be used for B2M measurement is 2 μL. The CRM including its B2M certified value was accepted as European Reference Material (ERM®) after peer evaluation by the partners of the European Reference Materials consortium.. CERTIFICATION REPORT The certification of the mass concentration of beta-2-microglobulin in human serum: ERM-DA470k/IFCC Guy Auclair, Ingrid Zegers, Amalia Muñoz, Virginie Trégoat, Stefanie Trapmann, Giampaolo Merlini, Yoshi Itoh, Joanna Sheldon, Heinz Schimmel, Hendrik Emons (1)European Commission, Joint Research Centre Institute for Reference Materials and Measurements (IRMM)
منابع مشابه
Analysis of the physicochemical state of C-reactive protein in different preparations including 2 certified reference materials.
BACKGROUND Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC was intended to fully replace ERM-DA470. However, the new material was not suit...
متن کاملCharacterization of the new serum protein reference material ERM-DA470k/IFCC: value assignment by immunoassay.
BACKGROUND The availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability i...
متن کاملCERTIFICATION REPORT The certification of the catalytic activity concentration of alanine aminotransferase in ERM®-AD454k/IFCC
This report describes the production of ERM®-AD454k/IFCC, which is a material certified for the catalytic activity concentration of alanine aminotransferase (ALT). This material was produced in collaboration with the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) following ISO Guide 34:2009 and it is certified in accordance with ISO Guide 35:2006. The starting ma...
متن کاملThe importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.
BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...
متن کاملCommutability of the ERM-DA470k reference material for two assays measuring serum albumin using immunochemical principles.
The standardization of measurements is a high-priority in Laboratory Medicine; its purpose being to achieve closer comparability of results for the same analyte obtained using different commercial systems (1). The promotion of result traceability to available higher-order reference measurement procedures and reference materials is the recommended approach (2). A major prerequisite for guarantee...