Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale.

نویسندگان

  • Stefano Maffè
  • Pierfranco Dellavesa
  • Franco Zenone
  • Anna Maria Paino
  • Paola Paffoni
  • Antonello Perucca
  • Daniela Kozel
  • Fabiana Signorotti
  • Massimo Bielli
  • Umberto Parravicini
  • Nicolò Franchetti Pardo
  • Lorenzo Cucchi
  • Alain Guillaime Aymele
  • Marco Zanetta
چکیده

AIMS Transoesophageal echocardiography (TEE) with contrast administration is still considered as the reference method for the detection of patent foramen ovale (PFO) with interatrial shunt, but it is a semi-invasive exam. The aim of the present study is to evaluate a role of two- and three-dimensional transthoracic echocardiography (TTE and R3DTE) as a diagnostic alternative to transcranial Doppler ultrasound (TCD) and TEE for detection of atrial right-to-left shunt. METHODS AND RESULTS Seventy-five patients with history of cerebrovascular events were subjected to four diagnostic examinations: TCD, TTE, R3DTE, and TEE, with bubble contrast. Bubbles in the left atrium within three cardiac cycles were considered diagnostic for PFO and later as a pulmonary shunt. Greater than 20 bubbles in the left atrium were considered a large shunt and <20 a small shunt. Every exam was read blinded to the results of the others. From the 75 enrolled patients, 62 (82.6%) patients showed right-to-left shunt with TEE; the results were also positive in 53 patients using TCD (70.6%), in 53 using R3DTE (70.6%), and in 55 using TTE (73.3%) (P = NS). There is a statistically significant superiority for TEE in the capacity of detecting shunts compared with TCD (P < 0.024), TTE (P < 0.018), and R3DTE (P < 0.018). The TEE presents a superior ability to recognize mild/moderate interatrial shunts respect to other exams (P = 0.003), without differences for shunts of high degree. In comparison to the TEE, the sensitivity is 89% for TTE, 88% for R3DTE, and 85% for TCD; the specificity is 100% for TTE and R3DTE, and 90% for TCD; the positive predictive value is 100% for TTE and R3DTE, and 98% for TCD; and the negative predictive value is 65% for TTE, 65% for R3DTE, and 53% for TCD. Considering only for mild/moderate shunts, the diagnostic accuracy is clearly inferior (sensitivity 63% for TTE, 58% for R3DTE, and 53% for TCD). CONCLUSION In this cohort of patients, TEE confirms the role of 'gold standard' exam for the detection of PFO; the non-invasive methods, and the TTE in particular, present a good diagnostic accuracy, but are inferior to the TEE because of the low negative predictive value and the non-optimal detection of small shunts. If the only purpose of TEE is the detection of significative interatrial shunt, TEE can be replaced by TTE. The R3DTE presents a good diagnostic accuracy, provides a better anatomical definition of the interatrial septum, and may have a role in this setting of patients, but does not add a lot to the TTE for the diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients.

AIMS The comparison of three imaging methods to determine which is the most accurate and reliable for the detection of right-to-left shunt. METHODS AND RESULTS One hundred and seven patients who were hospitalized for stroke underwent: a transthoracic echocardiography (TTE) using second harmonic, a transcranial Doppler (TCD) and a transesophageal echocardiography (TEE) from August 2003 to Apri...

متن کامل

Foramen Ovale in Stroke Patients

Background and Purpose: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in...

متن کامل

Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts.

AIMS To assess transthoracic echocardiography (TTE) using second harmonic imaging with Valsalva manoeuvre compared to transesophageal echocardiography (TEE) for the diagnosis of right to left cardiac and pulmonary shunts. METHODS AND RESULTS One hundred and ten patients referred for TEE underwent TTE with bubble contrast. Bubbles in the left atrium within three cardiac cycles were considered ...

متن کامل

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

Features of carcinoid heart disease identified by 2- and 3-dimensional echocardiography and cardiac MRI.

BACKGROUND Carcinoid heart disease is a rare form of valvular heart disease. We sought describe the spectrum of carcinoid heart disease identified by echocardiography and cardiac MRI. METHOD AND RESULTS Two hundred fifty-two patients with carcinoid syndrome underwent a range of investigations including 2D transthoracic echocardiography, 3D transthoracic echocardiography and transesophageal ec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2010