Glandular dose in breast computed tomography with synchrotron radiation.

نویسندگان

  • G Mettivier
  • C Fedon
  • F Di Lillo
  • R Longo
  • A Sarno
  • G Tromba
  • P Russo
چکیده

The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation from a synchrotron radiation source in the energetic range from 8 to 50 keV with 1 keV intervals, to evaluate the MGD. The code was validated with literature data, in terms of mammographic normalized glandular dose coefficients (DgN) and with ad hoc experimental data, in terms of computed tomography dose index (CTDI). Simulated cylindrical phantoms of different sizes (diameter at phantom base 8, 10, 12, 14 or 16 cm, axial length 1.5 times the radius) and glandular fraction by weight (0%, 14.3%, 25%, 50%, 75% and 100%) were implemented into the code. The validation of the code shows an excellent agreement both with previously published work and in terms of DgN and CDTI measurements. The implemented simulations show a dependence of the glandular dose estimate on the vertical dimension of the irradiated zone when a partial organ irradiation was implemented. Specific normalized coefficients for calculating the MGD to the whole breast or to the single irradiated slice were reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

نتایج یک کُد فرترن برای محاسبه دوز غده‌ای در ماموگرافی با استفاده از پارامترهای Sobol-Wu

Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

AbstractID: 12899 Title: Dosimetric Characterization of a Dedicated Breast Computed Tomography Clinical Prototype System

ID: 12899 Title: Dosimetric Characterization of a Dedicated Breast Computed Tomography Clinical Prototype System Purpose: To determine the radiation dosimetry characteristics of a dedicated breast computed tomography (BCT) clinical prototype system. Method and Materials: The relevant parameters of the BCT system were replicated in a Monte Carlo simulation program based on the Geant4 toolkit. To...

متن کامل

Dose Reduction Methods in Chest Computed Tomography

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 61 2  شماره 

صفحات  -

تاریخ انتشار 2016