Does standing or sitting position of the anesthesiologist in the operating theatre influence sevoflurane exposure during craniotomies?

نویسندگان

  • Péter Sárkány
  • Béla Tankó
  • Éva Simon
  • Judit Gál
  • Béla Fülesdi
  • Csilla Molnár
چکیده

BACKGROUND Exposure of the OR staff to inhalational anesthetics has been proven by numerous investigators, but its potential adverse effect under the present technical circumstances is a debated issue. The aim of the present work was to test whether using a laminar flow air conditioning system exposure of the team to anesthetic gases is different if the anesthetist works in the sitting as compared to the standing position. METHODS Sample collectors were placed at the side of the patient and were fixed at two different heights: at 100 cm (modelling sitting position) and 175 cm (modelling standing position), whereas the third collector was placed at the independent corner of the OR. Collected amount of sevoflurane was determined by an independent chemist using gas chromatography. RESULTS At the height of the sitting position the captured amount of sevoflurane was somewhat higher (median and IQR: 0.55; 0.29-1.73 ppm) than that at the height of standing (0.37; 0.15-0.79 ppm), but this difference did not reach the level of statistical significance. A significantly lower sevoflurane concentration was measured at the indifferent corner of the OR (0.14; 0.058-0.36 ppm, p < 0.001). CONCLUSIONS Open isolation along with the air flow due to the laminar system does not result in higher anesthetic exposure for the sitting anesthetist positioned to the side of the patient. Evaporated amount of sevoflurane is below the accepted threshold limits in both positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of variation in cardiocirculatory parameters with different body positions during isometric exercise in young adult males.

Introduction: To study the effects of exercise, how important it is to choose a posture? We aimed to characterize the possible impact of different body positions on cardiovascular parameters during and after sustained isometric handgrip (IHG) exercise.&nbsp;Materials and Methods: Cross sectional study was carried out in 33 young adult males (mean age: 19.21&plusmn;1.083 years). We recorded Bloo...

متن کامل

فعالیت عضلات ارکتوراسپاینا هنگام استراحت در وضعیت های مختلف در بیماران مبتلا به اسکولیوز نوجوانی ناشناخته

Background &&nbsp;Aims:&nbsp; Scoliosis is linked with asymmetrical compression loads induced by trunk muscles and external loads. The objective of this study was to measure the electrical activity of bilateral erector spinae muscles during the rest in the standing, sitting and lying positions. Materials & Methods: Ten patients with double curvature (right thoracic and left lumbar) scoliosis...

متن کامل

Exposure to sevoflurane and nitrous oxide during four different methods of anesthetic induction.

UNLABELLED The National Institute for Occupational Safety and Health-recommended exposure levels for nitrous oxide exposure are 25 ppm as a time-weighted average over the time of exposure. The exposure limit for halogenated anesthetics (without concomitant nitrous oxide exposure) is 2 ppm. Inhaled sevoflurane provides an alternative to i.v. induction of anesthesia. However, the inadvertent rele...

متن کامل

Investigation of the Effect of Voiding Position on Uroflometric Parameters and Voiding Residue in Healthy Volunteers in Imam Reza Hospital, Mashhad, Iran

Background & Aims: Uroflowmetry is a common procedure to examine the lower urinary tract system. Uroflowmetry results are affected by different factors. In this study, the effect of voiding position on uroflowmetric parameters and voiding residue were investigated in healthy subjects. Methods: This descriptive–analysis study was performed on 41 healthy volunteers with mean age of 33.22 ± 9.45 r...

متن کامل

بررسی مقایسه‌ای وضعیت ایستاده و نشسته از نظر حداکثر گشتاور اکستانسوری ایزومتریک ستون فقرات کمری در زوایای مختلف فلکسیون آن توسط دستگاه 200Isostation B- در مردان 30-20 سال

Today, Isostation B-200 is one of the most familiar for assessing low back muscles function.This study that is a Quasi-Experimental design was done on 30 healthy men (mean age~26.4 years). The aim of this research is to determine the best and worst motor efficiency in standing and sitting position following torque measurement. In this research maximum torque of low back extensor muscles...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016