Effect of a light-emitting diode on composite polymerization shrinkage and hardness.

نویسندگان

  • Bryan Nakfoor
  • Peter Yaman
  • Joseph Dennison
  • Alberto Herrero
چکیده

PURPOSE This study evaluated the effect of light-emitting diodes (LEDs) on polymerization shrinkage and bottom-to-top hardness ratios of composites. MATERIALS AND METHODS Six LEDs (Elipar FreeLight, 3M ESPE, St. Paul, MN, USA; Versalux, Centrix, Shelton, CT, USA; Ultra-Lume LED2, Ultradent, South Jordan, UT, USA; Zap LED only, CMS-Dental/Soft-Core Texas, North Richland Hills, TX, USA; Zap dual light; and L.E. Demetron I, Kerr Manufacturing Inc., Orange, CA, USA) and a quartz-tungsten-halogen (QTH) light (Optilux 501, Kerr Manufacturing Inc.) were tested. Ten specimens each of a microhybrid (Point 4, Kerr Manufacturing, Inc.) and a hybrid (Filtek Z250, 3M ESPE, St. Paul, MN, USA) composite, measuring 2 mm thick by 5 mm in diameter, were polymerized using each of the lights. Linear shrinkage was recorded using a contactless displacement instrument. Ten specimens were also polymerized with each light to determine the Knoop hardness number (KHN) at the top and bottom surfaces. RESULTS For the microhybrid, Zap dual light had the least volumetric shrinkage 2.08% (+/- 0.33) and Elipar FreeLight had the highest 3.02% (+/- 0.73). There was no significant difference (p < or = .05) in shrinkage for the LEDs when compared with the Optilux 501. The hybrid showed the least amount of shrinkage with the L.E. Demetron I, 1.42% (+/- 0.12), and the greatest with the Zap dual light, 2.47% (+/- 0.31). The Ultra-Lume LED2 (p < or = .05) and Zap LED and dual light (p < or = .001) had significantly greater shrinkage than did the Optilux 501. Zap LED had the lowest depth of cure with a bottom KHN of 11.46 (+/- 2.71) and 33.62 (+/- 3.57) for the microhybrid and hybrid, respectively. The L.E. Demetron I had the highest bottom hardness value for the microhybrid, with a value of 40.65 (+/- 1.50). The Optilux 501 had the highest bottom hardness value for the hybrid, with a value of 62.03 (+/- 0.82). The Zap LED and dual light and Versalux lights had significantly lower bottom-to-top hardness ratios than did the QTH (p < or = .001) with the microhybrid. CONCLUSIONS There was no statistically significant difference in shrinkage for the microhybrid with any of the lights tested. The hybrid, however, showed significantly less shrinkage with the halogen compared with the Ultra-Lume LED2 and Zap LED and dual light. All LEDs had equal or lower bottom hardness values than did the QTH, except for L.E. Demetron I with the microhybrid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of dual-peak LED unit on the polymerization of coinitiator-containing composite resins.

The purpose of the present study was to evaluate the effect of dual-peak LED on the polymerization of coinitiator-containing composite resins. For this, microhardness, degree of conversion (DC), and polymerization shrinkage were evaluated. Specimens (coinitiator-containing: Aelite LS Posterior, Tetric EvoCeram, and Vit-l-escence; only camphorquinone-containng: Filtek Z350 and Grandio) were ligh...

متن کامل

Effect of Shade on Immediate and Post-Curing Polymerization Shrinkage of Composite Resin

Background and Aim: Minimizing the polymerization shrinkage of composite resins is a critical goals in composite restorations. Many factors affect polymerization shrinkage. This study aimed to evaluate the effect of composite resin shade on polymerization shrinkage. Materials and Methods: In this in vitro study, 14 composite discs measuring 1.5×8 mm were fabricated. The samples were prepared u...

متن کامل

Curing Efficacy of Light Emitting Diodes of Dental Curing Units

BACKGROUND AND AIMS The aim of the present study was to compare the efficacy of quartz tungsten halogen (QTH) and light emitting diode (LED) curing lights on polymerization of resin composite. MATERIALS AND METHODS A hybrid resin composite was used to prepare samples which were cured using two QTH and ten LED light curing sources. Twelve groups, each containing ten samples, were prepared usin...

متن کامل

Effectiveness of second-generation light-emitting diode (LED) light curing units.

AIM The purpose of this study was to evaluate the effectiveness of three commercially available light emitting diode (LED) light curing units (LCU) (Elipar FreeLight--3M ESPE; UltraLume LED2--Ultradent; and Single V--BioArt) for polymerizing Z250-A3 composite (3M ESPE) using Knoop hardness, polymerization depth, and flexural strength properties. METHODS AND MATERIALS The XL 2500 (3M ESPE) LCU...

متن کامل

Effect of diode laser and light-emitting diode (LED) activated bleaching with 35% hydrogen peroxide on microleakage of class-V composite restorations: An in vitro study

Introduction: Residual oxygen-free radicals of bleaching agents before composite restorations can increase microleakage in enamel and dentin margins, and also various bleaching techniques are being developed using light sources. The present study was conducted to compare the effect of diode laser bleaching and LED activated bleaching on the microleakage of composite restorations. Materials & M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2005