Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study
نویسندگان
چکیده
BACKGROUND In critical care units, pupil examination is an important clinical parameter for patient monitoring. Current practice is to use a penlight to observe the pupillary light reflex. The result seems to be a subjective measurement, with low precision and reproducibility. Several quantitative pupillometer devices are now available, although their use is primarily restricted to the research setting. To assess whether adoption of these technologies would benefit the clinic, we compared automated quantitative pupillometry with the standard clinical pupillary examination currently used for brain-injured patients. METHODS In order to determine inter-observer agreement of the device, we performed repetitive measurements in 200 healthy volunteers ranging in age from 21 to 58 years, providing a total of 400 paired (alternative right eye, left eye) measurements under a wide variety of ambient light condition with NeuroLight Algiscan pupillometer. During another period, we conducted a prospective, observational, double-blinded study in two neurocritical care units. Patients admitted to these units after an acute brain injury were included. Initially, nursing staff measured pupil size, anisocoria and pupillary light reflex. A blinded physician subsequently performed measurement using an automated pupillometer. RESULTS In 200 healthy volunteers, intra-class correlation coefficient for maximum resting pupil size was 0.95 (IC: 0.93-0.97) and for minimum pupil size after light stimulation 0.87 (0.83-0.89). We found only 3-pupil asymmetry (≥ 1 mm) in these volunteers (1.5% of the population) with a clear pupil asymmetry during clinical inspection. The mean pupil light reactivity was 40 ± 7%. In 59 patients, 406 pupillary measurements were prospectively performed. Concordance between measurements for pupil size collected using the pupillometer, versus subjective assessment, was poor (Spearmen's rho = 0.75, IC: 0.70-0.79; P < 0.001). Nursing staff failed to diagnose half of the cases (15/30) of anisocoria detected using the pupillometer device. A global rate of discordance of 18% (72/406) was found between the two techniques when assessing the pupillary light reflex. For measurements with small pupils (diameters <2 mm) the error rate was 39% (24/61). CONCLUSION Standard practice in pupillary monitoring yields inaccurate data. Automated quantitative pupillometry is a more reliable method with which to collect pupillary measurements at the bedside.
منابع مشابه
Interrater Reliability of Pupillary Assessments.
BACKGROUND Subjective scoring of pupil reactivity is a fundamental element of the neurological examination for which the pupillometer provides an objective measure. METHODS This single-blinded observational study examined interrater reliability of pupil exam findings between two practitioners and between practitioners and a pupillometer. RESULTS From 2329 paired assessments, the interrater ...
متن کاملPupillometry-guided Intraoperative Remifentanil Administration versus Standard Practice Influences Opioid Use: A Randomized Study.
BACKGROUND Pupillometry has shown promising results for assessing nociception in anesthetized patients. However, its benefits in clinical practice are not demonstrated. The aim of this prospective randomized study was to evaluate the impact of intraoperative pupillometry monitoring on perioperative opioid consumption in major gynecologic surgery. METHODS After receiving ethics committee appro...
متن کاملEEG utilization in Canadian intensive care units: A multicentre prospective observational study
PURPOSE We have previously shown that electroencephalography (EEG) may be an underutilized monitoring modality in a single general medical-surgical ICU, that does not have a specific neurocritical care consultation service or neurocritical care unit. The present study was designed to describe the pattern of EEG utilization across 3 academic ICUs in Ontario, Canada that use different models of n...
متن کاملCerebrospinal fluid penetration of meropenem in neurocritical care patients with proven or suspected ventriculitis: a prospective observational study
BACKGROUND Ventriculitis is a complication of temporary intraventricular drains. The limited penetration of meropenem into the cerebrospinal fluid (CSF) is well known. However, ventricular CSF pharmacokinetic data in patients with ventriculitis are lacking. The aim of this study was to evaluate meropenem pharmacokinetics in the serum and CSF of neurocritical care patients with proven or suspect...
متن کاملProphylaxis of Venous Thrombosis in Neurocritical Care Patients: An Evidence-Based Guideline: A Statement for Healthcare Professionals from the Neurocritical Care Society.
The risk of death from venous thromboembolism (VTE) is high in intensive care unit patients with neurological diagnoses. This is due to an increased risk of venous stasis secondary to paralysis as well as an increased prevalence of underlying pathologies that cause endothelial activation and create an increased risk of embolus formation. In many of these diseases, there is an associated risk fr...
متن کامل