Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults.

نویسندگان

  • Alexis F Turgeon
  • Pierre C Nicole
  • Claude A Trépanier
  • Sylvie Marcoux
  • Martin R Lessard
چکیده

BACKGROUND Cricoid pressure (CP) is applied during induction of anesthesia to prevent regurgitation of gastric content and pulmonary aspiration. However, it has been suggested that CP makes tracheal intubation more difficult. This double-blind randomized study evaluated the effect of CP on orotracheal intubation by direct laryngoscopy in adults. METHODS Seven hundred adult patients undergoing general anesthesia for elective surgery were randomly assigned to have a standardized CP (n = 344) or a sham CP (n = 356) during laryngoscopy and intubation. After anesthesia induction and complete muscle relaxation, a 30-s period was allowed to complete intubation with a Macintosh No. 3 laryngoscope blade. The primary endpoint was the rate of failed intubation at 30 s. The secondary endpoints included the intubation time, the Cormack and Lehane grade of laryngoscopic view, and the Intubation Difficulty Scale score. RESULTS Groups were similar for demographic data and risk factors for difficult intubation. The rates of failed intubation at 30 s were comparable for the two groups: 15 of 344 (4.4%) and 13 of 356 (3.7%) in the CP and sham CP groups, respectively (P = 0.70). The grades of laryngoscopic view and the Intubation Difficulty Scale score were also comparable. Median intubation time was slightly longer in the CP group than in the sham CP group (11.3 and 10.4 s, respectively, P = 0.001). CONCLUSIONS CP applied by trained personnel does not increase the rate of failed intubation. Hence CP should not be avoided for fear of increasing the difficulty of intubation when its use is indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery

Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...

متن کامل

Conflicts of interest in expert-authored practice parameters, standards, guidelines, recommendations.

1. Amour J, Le Manach YL, Borel M, Lenfant F, Nicolas-Robin A, Carillion A, Ripart J, Riou B, Langeron O: Comparison of single-use and reusable metal laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia: A multicenter cluster randomized study. ANESTHESIOLOGY 2010; 112:325–32 2. Amour J, Marmion F, Birenbaum A, Nicolas-Robin A, Coriat P, Riou B, Langeron O...

متن کامل

Bispectral index response to cricoid pressure during induction of general anesthesia

BACKGROUND Because the effects of cricoid pressure (CP) on BIS values have not been evaluated, this prospective study was designed to assess the BIS values after application of CP in adult patients during the routine induction of general anesthesia. METHODS We randomly allocated 70 patients (ASA-I) aged 18-64 years, listed for elective surgery into two groups of cricoid (CP) and non-cricoid (...

متن کامل

Effect of cricoid pressure on laryngeal view during prehospital tracheal intubation: a propensity-based analysis.

BACKGROUND The benefit of cricoid pressure during tracheal intubation is still debated and, due to its potential negative impact on laryngeal views, its routine use is questioned. The goal of this study was to estimate its impact on laryngeal view. METHODS All patients intubated in the prehospital setting were included. Three different propensity score (PS) models were used and compared in te...

متن کامل

Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope System.

PURPOSE Cricoid pressure is commonly used during rapid sequence induction and intubation to minimize the risk of aspiration. The objective of the study was to evaluate the ease of fibreoptic (WuScope System(TM)) intubation in anesthetized adults receiving cricoid pressure. METHODS The intubation difficulty scale (IDS) was used to measure tracheal intubation difficulties in 33 patients undergo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 102 2  شماره 

صفحات  -

تاریخ انتشار 2005