A proximal femoral implant preserves physiological bone deformation: a biomechanical investigation in cadaveric bones.

نویسندگان

  • W Macdonald
  • L V Carlsson
  • C M Jacobsson
  • T Q Lee
چکیده

The aim of this study was to compare the perturbances in bone deformation patterns of the proximal femur due to a conventional cemented femoral stem and a novel uncemented implant designed on the principles of osseointegration. Five matched pairs of fresh frozen human femora were mechanically tested. Bone deformation patterns, measured with a video digitizing system under 1.5 kN joint force, showed that the cemented Spectron femoral implant caused significant alterations to the proximal femoral deformation pattern, whereas the Gothenburg osseointegrated titanium femoral implant did not significantly alter the bone behaviour (p < 0.05). Vertical micromotions measured under 1 kN after 1000 cycles were within the threshold of movement tolerable for bone ingrowth (21 microm for the Gothenburg system and 26 microm for the cemented implant).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The proximal femur--a second look at rational of implant design.

UNLABELLED Twenty five pairs (50 bones) of cadaveric femora were studied morphologically and radio logically using standardized techniques to obtain anthropometric data to evaluate the applicability of internationally designed implant and to generate a database for proximal femur to help in design for future implant if these were found unsuitable. MEASUREMENTS femoral head diameter, femoral n...

متن کامل

Reducing the risk of bone cement implantation syndrome during femoral arthroplasty.

Patients with pathologic hip fractures or impending pathologic proximal femur fractures are at a high risk for developing bone cement implantation syndrome during cemented femoral arthroplasty. Comorbid conditions of patients who sustain these fractures, including cardiopulmonary compromise and permeable, highly vascular bone related to metastatic disease, put them at risk for sudden death. Red...

متن کامل

A Biomechanical Comparison of Two Intramedullary Implants for Subtrochanteric Fracture in Two Healing Stages: A Finite Element Analysis

Background. The biomechanical effect of two implants, namely, proximal femoral nail antirotation for Asia (PFNA-II) and Expert Asian Femoral Nail (A2FN), for treating subtrochanteric fracture during healing stages, is still unclear. Methods. A 3D finite element model of an intact femur was constructed and validated. The fractured and postoperative models were accordingly produced. The postopera...

متن کامل

The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel alloy, consists of a nail, a peg and an anti-rotation pin. Upon positioning, th...

متن کامل

Tibial revision knee arthroplasty with metaphyseal sleeves: The effect of stems on implant fixation and bone flexibility

INTRODUCTION Revision total knee arthoplasty often requires modular implants to treat bone defects of varying severity. In some cases, it may not be clear which module size and implant combination (e.g. sleeve and stem) should be chosen for a specific defect. When balancing implant stability and osseointegration against stress-shielding, it is important to choose an appropriate implant combinat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 217 1  شماره 

صفحات  -

تاریخ انتشار 2003