D- and L-amino acids in Antarctic lakes: assessment of a very sensitive HPLC-MS method.

نویسندگان

  • Elena Barbaro
  • Roberta Zangrando
  • Marco Vecchiato
  • Clara Turetta
  • Carlo Barbante
  • Andrea Gambaro
چکیده

Amino acids represent a fraction of organic matter in marine and freshwater ecosystems, and a source of carbon, nitrogen and energy. L-Amino acids are the most common enantiomers in nature because these chiral forms are used during the biosynthesis of proteins and peptide. To the contrary, the occurrence of D-amino acids is usually linked to the presence of bacteria. We investigated the distribution of L- and D-amino acids in the lacustrine environment of Terra Nova Bay, Antarctica, in order to define their natural composition in this area and to individuate a possible relationship with primary production. A simultaneous chromatographic separation of 40 L- and D-amino acids was performed using a chiral stationary phase based on teicoplainin aglycone (CHIROBIOTIC TAG). The chromatographic separation was coupled to two different mass spectrometers--an LTQ-Orbitrap XL (Thermo Fisher Scientific) and an API 4000 (ABSciex)--in order to investigate their quantitative performance. High-performance liquid chromatography coupled with mass spectrometry methods were evaluated through the estimation of their linear ranges, repeatability, accuracy and detection and quantification limits. The high-resolution mass spectrometer LTQ-Orbitrap XL presented detection limits between 0.4 and 7 μg L (-1), while the triple quadrupole mass spectrometer API 4000 achieved the best detection limits reported in the literature for the quantification of amino acids (between 4 and 200 ng L (-1)). The most sensitive method, HPLC-API 4000, was applied to lake water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

Radioiodine D amino acids labeling of Rituximab, a new method for enhancing the radiopharmaceutical targetingand biostability

  Introduction: Radioimmunotherapy (RIT) is a very promising new therapy for the treatment of recurrent B-Cell non-Hodgkin's lymphoma (NHL). Iodine-131 is the most frequently used nuclide in clinical RIT, but its usefulness has been limited by dehalogenation of monoclonal antibodies labeled via conventional methods. To circumvent this problem, we have synthesized a tr...

متن کامل

Identification of amino acids in Securigera securidaca, a popular medicinal herb in Iranian folk medicine

Securigera securidaca (L.) Degen & Dorfl grows in different parts of Iran. The seeds of the species are used in Iranian folk medicine as an anti-diabetic agent. Many studies have established hypoglycemic effects of amino acids and in the present investigation, amino acids of Securigera securidaca seeds have been evaluated. The ground seeds were extracted using petroleum ether,...

متن کامل

A New Metal Tag for Highly Selective and Sensitive Analyses of Amino Acids and Dipeptides by HPLC/ICP-MS

We have developed a novel metal tag, bis(ethylenediamine)-4'-methyl-4-carboxybipyridine-ruthenium N-succinimidyl ester (ECRS) for sensitive analysis of amino acids using high performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS). ECRS is a functional reagent, containing an ester group at one end that can be activated to bind to amino group and a chelated r...

متن کامل

Performance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids

The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 406 22  شماره 

صفحات  -

تاریخ انتشار 2014