Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor.
نویسندگان
چکیده
OBJECTIVE To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to be limited by ceiling effects and more representative of everyday speech communication. DESIGN Four normal-hearing subjects were presented with speech processed through a real-time sine-excited vocoder having three, four, eight, or 12 channels. Amplitude envelopes extracted from each band modulated sinusoidal carrier signals placed at each band center frequency. Speech-spectrum shaped noise was added to speech before vocoder processing at three signal to noise ratios based on real-time measurements of speech level (+7, +12, +17 dB). RESULTS CDT rates increased significantly with number of channels up to eight in both quiet and noise, and decreased significantly with each increase in noise level from quiet. CONCLUSIONS The effects on CDT rates of the number of channels and speech-to-noise ratio are highly correlated with intelligibility measures for Hearing in Noise Test (HINT) sentences, consonants and vowels. However, HINT sentence scores even in noise show ceiling effects that obscure the advantages of processors with eight or more channels. Moderate levels of noise that have only slight effects on other measures significantly affected CDT rate. CDT rates with three or four bands of spectral information were much lower than asymptotic rates, especially in the presence of noise.
منابع مشابه
Modeling and Signal processing for Cochlear Implant to improve speech recognition
Cochlear implant Prostheses device is implanted in the inner ear and restore partial hearing to profound deaf people. A microphone that picks up the sound waves is applied to a signal processor, which then converts the sound into electrical signals. Then, the electrical signals are given to transmission system which transmits the pulses to the implanted electrodes. The laboratory speech process...
متن کاملRelationship between Working Memory, Auditory Perception and Speech Intelligibility in Cochlear Implanted Children of Elementary School
Objectives: This study examined the relationship between working and short-term memory performance, and their effects on cochlear implant outcomes (speech perception and speech production) in cochlear implanted children aged 7-13 years. The study also compared the memory performance of cochlear implanted children with their normal hearing peers. Methods: Thirty-one cochlear impl...
متن کاملEffects of simulated cochlear-implant processing on speech reception in fluctuating maskers.
This study investigated the effects of simulated cochlear-implant processing on speech reception in a variety of complex masking situations. Speech recognition was measured as a function of target-to-masker ratio, processing condition (4, 8, 24 channels, and unprocessed) and masker type (speech-shaped noise, amplitude-modulated speech-shaped noise, single male talker, and single female talker)....
متن کاملSpeech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.
Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear i...
متن کاملRelationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery
Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them. Materials and Methods: Ten children with a m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2001