An improved fluorometric assay of rat serum and plasma converting enzyme.

نویسندگان

  • R A Santos
  • E M Krieger
  • L J Greene
چکیده

The most sensitive nonradiometric routine assay for angiotensin-converting enzyme (ACE) activity uses fluorometry to detect His-Leu released from Hip-His-Leu. Our results indicate that, in contrast to human serum, rat serum and plasma contain large and variable amounts of dipeptidase activity that lead to a subestimation of the ACE activity measured in 0.1 M potassium phosphate buffer, pH 8.3, containing 0.3 M NaCl, the most commonly used assay for human serum and tissue ACE. We describe and validate an assay for 1 to 10 microL rat and human serum or plasma using 5 mM Hip-His-Leu in 500 microL of 0.4 M sodium borate buffer, pH 8.3, containing 0.9 M NaC1 at 37 degrees C that reduced the subestimation error to less than or equal to 3% (rat serum) and less than or equal to 0.1% (human serum) and increased the ACE activity twofold to threefold. The Km and Vmax are reported for rat serum ACE (Hip-His-Leu) and dipeptidase (His-Leu) in borate buffer and phosphate buffer. Rat serum ACE hydrolysis of Hip-His-Leu measured by fluorometry correlated (r = 0.99, p less than 0.05) with the hydrolysis of angiotensin I measured by high-performance liquid chromatography. A direct method based on amino acid analysis is described for evaluating the dipeptidase error of complex mixtures such as tissue extracts and other physiological fluids. We have found that the assay can be used to measure ACE activity in 25 samples (in duplicate) in 2 hours with small intraassay (2.2%) and interassay (3.9%) coefficients of variation.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Serum and Tissues Angiotensin Converting Enzyme (ACE) Activity in Rat with Gentamicin Induced Renal Toxicity

The angiotensin I-converting enzyme (ACE) converts the inactive angiotensin I molecule to the active angiotensin II. ACE is rich in epithelium, endothelium, and neuroepithelial cells and it found largely on the brush border of intestine and kidney proximal tubules. ACE also presents in the serum. Some pulmonary and renal toxic drugs change the serum and tissue ACE contents. In this research ACE...

متن کامل

Angiotensin converting enzyme variability in hypertensive and normotensive rats.

Recent data have revealed biological and genetic variability in normotensive Wistar-Kyoto rats, which are considered to be the most appropriate control strain for spontaneously hypertensive rats. To investigate the possibility that angiotensin converting enzyme activity could be affected by this variability, we measured plasma and tissue (lung, heart, renal cortex, renal medulla, and adrenal gl...

متن کامل

Fluorometric assay for angiotensin converting enzyme in human serum by centrifugal analysis.

Due to its action on angiotensin I and bradykinin, angiotensin converting enzyme (ACE, dipeptidyl carboxypeptidase, EC 3.4.15.1) plays a crucial role in blood pressure regulation [l]. Attention was focused on this enzyme when Lieberman observed elevated serum ACE levels in active sarcoidosis [2]. Because ACE is a sensitive index both in assessing the clinical status of this disease and in monit...

متن کامل

Enzyme-Linked Immunosorbent Assay of Progesterone in Serum Using Penicillinase as Label

An enzyme-linked immunosorbent assay (ELISA) for progesterone measurement in serum or plasma samples using penicillinase as label enzyme is reported. A C3 and C11 derivatives of progesterone were prepared and conjugated to bovin serum albumin (BSA). Polyclonal antibody against these two immunogens were prepared in New Zealand white rabbits. Purified Ig fractions of antibodies were immobilized o...

متن کامل

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 1985