A method for determining the mechanical characteristics of orthotic knee joints.

نویسندگان

  • R P Scothern
  • G R Johnson
چکیده

All orthotic equipment must operate at the highest possible standards of safety and, should structural failure of a loaded component occur, there must be a minimal possibility of injury to the user. Because of the lack of definitive data on the in-service loading of lower limb orthoses it is not possible to base a test procedure on "real" loading conditions. In this paper a method of destructive testing, based on the assumption that the predominant loading consists of bending about the medio-lateral and anterior-posterior axes, is described. This method makes it possible to measure the bending strength of a knee joint side member assembly and to define the brittleness of the failure. It is suggested that the latter definition makes it possible to predict the potential safety of a particular knee joint should in-service failure occur. Some laboratory failures are described and recommendations, based on the test programme, are made for new joint designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A method for location of prosthetic and orthotic knee joints.

2 Chief, Orthopedic Surgery, Duke University Medical Center, Durham, N. C; Chief, Orthopedic and Prosthetic Appliance Clinic Team, Veterans Administration Hospital, Durham, N. C. When it is necessary to use a mechanical knee joint, whether it be in a below-knee prosthesis or a long-leg brace, ideally there should be no relative motion between the patient's limb and the appliance during its use....

متن کامل

Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms

The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the c...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

Muscle moment and angle of hip, knee and ankle joints in a seven- link model of backpack sprayer operator

Background and Aim: Carriage of backpack sprayers is an inevitable part of agricultural operations that increases the risk of injury along with undesirable changes in walking mechanics. The purpose of this study is to formulate the muscle moment changes in the hip, knee and ankle for the backpack sprayer operator body. Methods: In this study, a seven-link sprayer operator model is designed and...

متن کامل

Preliminary clinical experience of a contracture correction device.

Joint contractures which do not respond to conventional physiotherapy can be difficult to treat. Serial plastering has been used effectively but is expensive, inconvenient to the patient and does not permit daily hygiene or clinical inspection. A mechanical device has been developed consisting a hinged orthosis which spans the affected joint to which is attached a gas strut to provide a correct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 1984