Redundancy reduction for improved display and analysis of body surface potential maps. I. Spatial compression.

نویسندگان

  • R L Lux
  • A K Evans
  • M J Burgess
  • R F Wyatt
  • J A Abildskov
چکیده

The Karhunen-Loeve technique of random process representation was investigated as a method of quantitatively characterizing body surface potential maps. One hundred ninety-two lead body surface potential maps from 124 normal subjects and 97 patients with independently documented heart disease were used in the study. Each map frame in QRS and ST-T of 34 maps in a test set was represented as a linear sum of orthonormal distributions derived from the covariance matrix estimated from all QRS frames in the 221 training maps. A 16:1 reduction in spatial data of the test set was achieved with rms errors of 45 and 21 microV in QRS and ST-T, respectively. Results suggest that 12 independent waveforms, derived from the 192 measured ECGs, may be used in place of those 192 ECGs. In addition to providing a convenient and familiar method of display for map data, the technique puts the data in an appropriate form for quantitative statistical analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Redundancy reduction for improved display and analysis of body surface potential maps. II. Temporal compression.

This paper describes use of the Karhunen-Loeve expansion to identify and reduce temporal redundancy in electrocardiographic body surface potential maps (192 body surface leads recorded simultaneously at 1 kHz/channel for approximately 600 msec). Temporal data compression of about 20 to 1 was obtained with accurate representation of the original data. Use of separate sets of orthonormal basis fu...

متن کامل

Redundancy Reduction for Improved Display and Analysis of Body Surface Potential Maps

The Karhunen-Loeve technique of random process representation was investigated as a method of quantitatively characterizing body surface potential maps. One hundred ninety-two lead body surface potential maps from 124 normal subjects and 97 patients with independently documented heart disease were used in the study. Each map frame in QRS and ST-T of 34 maps in a test set was represented as a li...

متن کامل

Highly Scalable Compression Method for Super Resolution Multi Spectral Images

This paper provides a new technique for lossy multispectral images compression at very high data rates. Image compression is becoming more and more important, as new multispectral instruments are going to generate very high data rates due to the increased spatial and spectral resolutions. The Lossless compression does not provide a sufficient degree of data volume reduction to meet the bandwidt...

متن کامل

Determining the Proper compression Algorithm for Biomedical Signals and Design of an Optimum Graphic System to Display Them (TECHNICAL NOTES)

In this paper the need for employing a data reduction algorithm in using digital graphic systems to display biomedical signals is firstly addressed and then, some such algorithms are compared from different points of view (such as complexity, real time feasibility, etc.). Subsequently, it is concluded that Turning Point algorithm can be a suitable one for real time implementation on a microproc...

متن کامل

Functional Surface Display of Laccase in a Phenol-Inducible Bacterial Circuit for Bioremediation Purposes

Background: Phenolic compounds, which are produced routinely by industrial and urban activities, possess dangers to live organisms and environment. Laccases are oxidoreductase enzymes with the ability of remediating a wide variety of phenolic compounds to more benign molecules. The purpose of the present research is surface display of a laccase enzyme with adhesin involved in diffuse adhesion (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 1981