Cardiac Resynchronization Therapy Using Quadripolar Versus Non‐Quadripolar Left Ventricular Leads Programmed to Biventricular Pacing With Single‐Site Left Ventricular Pacing: Impact on Survival and Heart Failure Hospitalization
نویسندگان
چکیده
BACKGROUND In cardiac resynchronization therapy (CRT), quadripolar (QUAD) left ventricular (LV) leads are less prone to postoperative complications than non-QUAD leads. Some studies have suggested better clinical outcomes. METHODS AND RESULTS Clinical events were assessed in 847 patients after CRT-pacing or CRT-defibrillation using either QUAD (n=287) or non-QUAD (n=560), programmed to single-site site LV pacing. Over a follow-up period of 3.2 years (median [interquartile range, 1.90-5.0]), QUAD was associated with a lower total mortality (adjusted hazard ratio [aHR]: 0.32, 95% confidence interval [CI], 0.20-0.52), cardiac mortality (aHR: 0.36, 95% CI, 0.20-0.65), and heart failure (HF) hospitalization (aHR: 0.62, 95% CI, 0.39-0.99), after adjustment for age, sex, New York Heart Association class, HF etiology, device type (CRT-pacing or CRT-defibrillation), comorbidities, atrial rhythm, medication, left ventricular ejection fraction, and creatinine. Death from pump failure was lower with QUAD (aHR: 0.33; 95% CI, 0.18-0.62), but no group differences emerged with respect to sudden cardiac death. There were no differences in implant-related complications. Re-interventions for LV displacement or phrenic nerve stimulation, which were lower with QUAD, predicted total mortality (aHR: 1.68, 95% CI, 1.11-2.54), cardiac mortality (aHR: 2.61, 95% CI, 1.66-4.11) and HF hospitalization (aHR: 2.09, 95% CI, 1.22-3.58). CONCLUSIONS CRT using QUAD, programmed to biventricular pacing with single-site LV pacing, is associated with a lower total mortality, cardiac mortality, and HF hospitalization. These trends were observed for both CRT-defibrillation and CRT-pacing, after adjustment for HF cause and other confounders. Re-intervention for LV lead displacement or phrenic nerve stimulation was associated with worse outcomes.
منابع مشابه
Quadripolar Leads in Cardiac€Resynchronization Therapy
Ma Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient’s specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing location...
متن کاملThe Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads
BACKGROUND Phrenic nerve stimulation (PNS) and high pacing thresholds (HPT) hinder biventricular stimulation in patients (pts) undergoing cardiac resynchronization therapy (CRT). A new quadripolar left ventricular (LV) lead (Quartet 1458Q, St. Jude Medical) with increased number of pacing configuration, might overcome this problem. METHODS All consecutive pts in whom a standard bipolar lead i...
متن کاملA comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study.
AIMS Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) lead...
متن کاملAcute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead.
AIMS Pacing from multiple sites in the left ventricle (LV) may bring about further resynchronization of the diseased heart compared with biventricular (BiV) pacing. We compared acute haemodynamic response (LV dP/dtmax) of multisite and BiV pacing using a quadripolar LV lead. METHODS AND RESULTS In 21 patients receiving cardiac resynchronization therapy, a quadripolar LV lead and conventional ...
متن کاملCardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long‐Term Follow‐Up from a Multicenter Registry
INTRODUCTION Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated. METHODS A total of 721 consecutive patients wi...
متن کامل