The Incidence of Riata Defibrillator Lead Failure: a Single-Center Experience

نویسندگان

  • Hye Bin Gwag
  • Jin Kyung Hwang
  • Kyoung Min Park
  • Seung Jung Park
  • Young Keun On
  • June Soo Kim
چکیده

Riata defibrillator leads were recalled due to a high failure rate. This study measured the incidence of externalized conductor (EC) and electrical dysfunction (ED) and sought to determine the predictors of ED with Riata defibrillator leads. We enrolled patients who received Riata® or Riata® ST silicone defibrillator leads at our center between January 2003 and December 2010. The presence of EC was evaluated with chest radiography. The incidence rates were measured at < 3 years, 3-5 years, and > 5 years after lead implantation. We also investigated the rates of ED and other clinical events during the follow-up period. A total of 44 patients were analyzed. The total cumulative incidence of EC was 27.3%. During the median dwell time (80 months), the incidence of ED was 22.7%. Patients with ED were younger (46.5 vs. 56.5 years, P = 0.018) and had a higher prevalence of cardiomyopathy than those without ED (60.0% vs. 20.6%, P = 0.043). ECs were most frequently detected in patients who underwent X-ray analysis 3-5 years after lead implantation (44.4%). In contrast, ED had a bimodal incidence pattern, with peaks at 5 years (7.0%) and 9 years (5.3%). There was no difference in ED-free survival rate between patients with and without EC (P = 0.628). Given the delayed occurrence of EC and ED after implantation of Riata defibrillator leads, long-term close monitoring is critically important.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of a novel silicone–polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions

AIM The purpose of this study was to determine if Optim™, a unique copolymer of silicone and polyurethane, protects Riata ST Optim and Durata implantable cardioverter-defibrillator (ICD) leads (SJM, St Jude Medical Inc., Sylmar, CA, USA) from abrasions that cause lead failure. METHODS AND RESULTS We searched the US Food and Drug Administration's (FDA's) Manufacturers and User Device Experienc...

متن کامل

Failure-free survival of the Durata defibrillator lead.

AIMS Given design similarities and a common manufacturer, there have been suspicions regarding the Durata™ defibrillator (ICD) lead, in the aftermath of the Riata™ class I recall. We therefore examined the failure-free survival rates of the Durata™ compared with the Riata™ and Sprint Quattro™ ICD leads. METHODS AND RESULTS All patients (n = 2475) implanted with a Durata (n = 828), Riata [n = ...

متن کامل

Shock-induced right ventricular pacing failure caused by a short circuit: Uncommon but life-threatening complication of the Riata lead

Introduction The Riata and Riata ST implantable cardioverter-defibrillator (ICD) leads, a narrow caliber silicone lead without an outer jacket, have been shown to be prone to structural and electrical failure. While much interest has been shown in potentially lethal high-voltage (HV) failures caused by electrical short circuits due to a breach in the ethylene tetrafluoroethylene (ETFE) insulati...

متن کامل

Fluoroscopic investigation of Riata® transvenous defibrillator leads.

BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...

متن کامل

Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family.

BACKGROUND The Food and Drug Administration recently issued a class I recall of the St. Jude Medical Riata implantable cardioverter-defibrillator lead presumably because of increased risk of electric failure and mechanical separation via inside-out abrasion. We sought to examine the incidence and time dependence of inside-out abrasion in asymptomatic patients implanted with the Riata lead. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2017