Evaluation of human hemispheric blood flow based on non invasive carotid blood flow measurements using the range-gated Doppler technique.
نویسندگان
چکیده
Common carotid blood flow (CCBF) was measured in 11 anesthetised patients without extracranial arterial disease (nine acute subarachnoid haemorrhages and two cases of head injury). The range-gated Doppler flowmeter with an adjustable range-gated time system and a double transducer probe was used to determine diameter, blood velocity, and blood flow of the common carotid artery. Values were, respectively, 5.9 +/- 1.1 mm, 13.8 +/- 6.1 cm . sec-1 and 387 +/- 183 cm3 . min-1. Mean cerebral blood flow (rCBF) measurements were simultaneously made by 133Xenon intra-arterial method, with a value of 22.28 +/- 5.96 ml . min-1 . 100 g. High correlation coefficient was found between CCBF and mean rCBF (r = 0.73, p less than 0.001). The range-gated Doppler flowmeter thus provides a non invasive and easily duplicated method for monitoring cerebral blood flow in anesthetized patients.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کاملTissue blood flow measurement by laser Doppler technique
Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...
متن کاملVibration Analysis of Carotid Arteries Conveying Non-Newtonian Blood Flow Surrounding by Tissues
The high blood rate that often occurs in arteries may play a role in artery failure and tortuosity which leads to blackouts, transitory ischemic attacks and other diseases. However, vibration and instability analysis of carotid arteries are lacking. The objective of this study is to investigate the vibration and instability of the carotid arteries conveying blood under axial tension with surrou...
متن کاملتغییر سرعت و مقایسه جریان خون نیمکرههای تکلمی در افراد سالم چپ و راست دست با سونوگرافی داپلر ترانس کرانیال عملکردی
Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tsty...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 13 3 شماره
صفحات -
تاریخ انتشار 1982