The design features of cemented femoral hip implants.
نویسندگان
چکیده
We undertook a review of the literature relating to the two basic stem designs in use in cemented hip replacement, namely loaded tapers or force-closed femoral stems, and the composite beam or shape-closed designs. The associated stem fixation theory as understood from in vitro studies and finite element modelling were examined with reference to the survivorship results for each of the concepts of fixation. It is clear that both design principles are capable of producing successful long-term results, providing that their specific requirements of stem metallurgy, shape and surface finish, preparation of the bone and handling of the cement are observed.
منابع مشابه
Bone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملMetal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants
BACKGROUND There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants. METHODS This paper r...
متن کاملDesign-related risk factors for revision of primary cemented stems
BACKGROUND AND PURPOSE Even small design variables of the femoral stem may influence the outcome of a hip arthroplasty. We investigated whether design-related factors play any role in the risk of non-aseptic revision of the 3 most frequently used primary cemented stem designs in the Swedish Hip Arthroplasty Register. PATIENTS AND METHODS We studied 71,184 primary cemented femoral stem implant...
متن کاملAssessing the dog as a model for human total hip replacement. Analysis of 38 canine cemented femoral components retrieved at post-mortem.
Post-mortem retrieval of canine, cemented femoral components was analysed to assess the performance of these implants in the dog as a model for human total hip replacement (THR). Mechanical testing and radiological analysis were performed to determine the stability of the implant and the quality of the cement. Thirty-eight implants from 29 dogs were retrieved after time intervals ranging from 0...
متن کاملUse of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial
Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 88 11 شماره
صفحات -
تاریخ انتشار 2006