Evaluating the endoscopic reference score for eosinophilic esophagitis: moderate to substantial intra- and interobserver reliability.

نویسندگان

  • Bram D van Rhijn
  • Marijn J Warners
  • Wouter L Curvers
  • Anja U van Lent
  • Noor L Bekkali
  • R Bart Takkenberg
  • Jaap J Kloek
  • Jacques J G H M Bergman
  • Paul Fockens
  • Albert J Bredenoord
چکیده

BACKGROUND AND STUDY AIMS Recently the Endoscopic Reference Score (EREFS) for endoscopic assessment of eosinophilic esophagitis was introduced, with good interobserver agreement for most signs. The EREFS has not yet been evaluated by other investigators and intraobserver agreement has not been assessed. The aim of this study was to further validate the EREFS by assessing interobserver and intraobserver agreement of endoscopic signs in patients with eosinophilic esophagitis. PATIENTS AND METHODS High-quality endoscopic images were made of the esophagus of 30 patients with eosinophilic esophagitis (age 36 years, range 23 - 46 years; 5 female), 6 of whom were in remission. At least three depersonalized images per patient were incorporated into a slideshow. Images were scored by four expert and four trainee endoscopists who were blinded to the patients' conditions. Interobserver agreement was assessed. After 4 weeks, the images were rescored in a different order to assess intraobserver agreement. RESULTS Interobserver agreement was substantial for rings (κ 0.70), white exudates (κ 0.63), and crepe paper esophagus (κ 0.62), moderate for furrows (κ 0.49) and strictures (κ 0.54), and slight for edema (κ 0.12). Intraobserver agreement was substantial for rings (median κ 0.64, IQR 0.46 - 0.70), furrows (median κ 0.69, IQR 0.50 - 0.89), and crepe paper esophagus (median κ 0.69, IQR 0.62 - 0.83), moderate for white exudates (median κ 0.58, IQR 0.54 - 0.71) and strictures (median κ 0.54, IQR 0.33 - 0.70), and less than chance for edema (median κ 0.00, IQR 0.00 - 0.29). Inter- and intraobserver agreement was not substantially different between expert and trainee endoscopists. CONCLUSIONS Using the EREFS, endoscopic signs of eosinophilic esophagitis were scored consistently by expert and trainee endoscopists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variable reliability of endoscopic findings with white-light and narrow-band imaging for patients with suspected eosinophilic esophagitis.

BACKGROUND & AIMS Endoscopic findings have been used to support a diagnosis of eosinophilic esophagitis (EoE) and to assess response to therapy, but their reliability is unknown. The aim of the study was to assess inter- and intraobserver reliability of endoscopic findings with white-light endoscopy and to assess changes in interobserver reliability when narrow band imaging (NBI) was added to w...

متن کامل

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Reflectance confocal microscopy for the diagnosis of eosinophilic esophagitis: a pilot study conducted on biopsy specimens.

BACKGROUND Diagnosis of eosinophilic esophagitis (EoE) currently requires endoscopic biopsy and histopathologic analysis of the biopsy specimens to count intraepithelial eosinophils. Reflectance confocal microscopy (RCM) is an endomicroscopy technology that is capable of obtaining high-resolution, optically sectioned images of esophageal mucosa without the administration of exogenous contrast. ...

متن کامل

Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom

PURPOSE To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. METHODS Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) perf...

متن کامل

تفسیر نتایج ایمنوهیستوشیمی بیان HER2/neu در سرطان مهاجم پستان: بررسی توافق بین مشاهده‌کنندگان و در دو بار مشاهده توسط یک نفر

    Background and Aim: The accurate determination of HER-2 in invasive breast cancer has become a critical issue, particularly in context of the results of Herceptin adjuvant therapy. The aim of this study was to evaluate inter- and intraobserver reproducibility of assessment of HER2/neu immunostaining in invasive breast cancerMaterials and Methods: This study was cross sectional and the conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 2014