Evaluation of a pen injector system for growth hormone treatment

نویسندگان

  • Peter D Gluckman
  • Wayne S Cutfield
چکیده

The increasing use of human growth hormone (hGH) treatment has resulted in the introduction of a number of alternative delivery systems to conventional syringe and needle administration. We examined patients' evaluation of a new delivery system, the Kabipen (KabiVitrum). We also assessed the accuracy of hGH delivery by the Kabipen. Of the 77 survey respondents 13 had used only the Kabipen, 14 the syringe only, and 50 had used both systems. Altogether 46 (92%) of those who had used both systems preferred the Kabipen. Children over 10 years were more likely to self administer hGH with the Kabipen (64%) than syringe (25%). Patient instructions, convenience of use, and comfort of use were rated better for the Kabipen than syringe. With a dose setting of 2 units the Kabipen delivered a mean (SD) of 1-997 (0.073) units with 102*5% recovery from a unit cartridge. In summary the Kabipen is an accurate device clearly preferred by the majority of hGH recipients surveyed. Department of Paediatrics, University of Auckland, Private Bag, Auckland, New Zealand Peter D Gluckman Wayne S Cutfield Correspondence to: Dr Cutfield. Accepted 5 February 1991 Clinicians prescribing human growth hormone (hGH) are aware of the problems that limit the acceptance of this form of treatment by many families. Recent studies have unequivocally shown the value of daily rather than traditional injections three times a week. 2 With the rapid increase in utilisation of hGH as a result of its wider availability alternative delivery systems have been developed to facilitate ease of ad-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum method for administration of biosynthetic human growth hormone: a randomised crossover trial of an Auto Injector and a pen injection system.

The use of optimum conventional growth hormone administration, using a growth hormone vial combined with an Auto Injector, was compared with a pen injection system using a cartridge of growth hormone. In both methods of administration the concentration of growth hormone was 16 IU/ml. Thirty patients (22 boys, eight girls) who had all previously been treated with growth hormone (4 IU/ml) adminis...

متن کامل

Optimum method for administration of biosynthetic human growth hormone: a randomised

The use of optimum conventional growth hormone administration, using a growth hormone vial combined with an Auto Injector, was compared with a pen injection system using a cartridge of growth hormone. In both methods of administration the concentration of growth hormone was 16 IU/ml. Thirty patients (22 boys, eight girls) who had all previously been treated with growth hormone (4 IU/ml) adminis...

متن کامل

Optimum method for administration of biosynthetic human growth hormone:

The use of optimum conventional growth hormone administration, using a growth hormone vial combined with an Auto Injector, was compared with a pen injection system using a cartridge of growth hormone. In both methods of administration the concentration of growth hormone was 16 IU/ml. Thirty patients (22 boys, eight girls) who had all previously been treated with growth hormone (4 IU/ml) adminis...

متن کامل

User assessment of Norditropin NordiFlex®, a new prefilled growth hormone pen: a Phase IV multicenter prospective study

UNLABELLED BACKGROUNDAIM: In growth disorders, ensuring long-term growth hormone therapy (GHT) remains a challenge that might compromise the clinical outcome. Consequently, strategies aiming at alleviating the burden of daily injection might improve the treatment benefit. The study reported here was performed to assess the ease of use of Norditropin NordiFlex(®) (Novo Nordisk, Princeton, NJ, US...

متن کامل

Evaluation of a pen injector system for growth hormone treatment.

The increasing use of human growth hormone (hGH) treatment has resulted in the introduction of a number of alternative delivery systems to conventional syringe and needle administration. We examined patients' evaluation of a new delivery system, the Kabipen (Kabi-Vitrum). We also assessed the accuracy of hGH delivery by the Kabipen. Of the 77 survey respondents 13 had used only the Kabipen, 14 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007