Fluid losses and hydration status of industrial workers under thermal stress working extended shifts.

نویسندگان

  • D J Brake
  • G P Bates
چکیده

AIMS To assess whether workers under significant thermal stress necessarily dehydrated during their exposure and whether "involuntary dehydration" was inevitable, as supported by ISO 9866 and other authorities. Other objectives were to quantify sweat rates against recommended occupational limits, to develop a dehydration protocol to assist with managing heat exposures, and to understand the role of meal breaks on extended shifts in terms of fluid replacement. METHODS A field investigation to examine the fluid consumption, sweat rates, and changes in the hydration state of industrial workers on extended (10, 12, and 12.5 hour) shifts under significant levels of thermal stress (wet bulb globe temperature (WBGT) >28 degrees C) was conducted on 39 male underground miners. Urinary specific gravity was measured before, during, and at the completion of the working shift. Environmental conditions were measured hourly during the shift. Fluid replacement was measured during the working periods and during the meal breaks. RESULTS Average environmental conditions were severe (WBGT 30.9 degrees C (SD 2.0 degrees C), range 25.7-35.2 degrees C). Fluid intake averaged 0.8 l/h during exposure (SD 0.3 l/h, range 0.3-1.5 l/h). Average urinary specific gravity at start, mid, and end of shift was 1.0251, 1.0248, and 1.0254 respectively; the differences between start and mid shift, mid and end shift, and start and end shift were not significant. However, a majority of workers were coming to work in a moderately hypohydrated state (average urinary specific gravity 1.024 (SD 0.0059)). A combined dehydration and heat illness protocol was developed. Urinary specific gravity limits of 1.022 for start of shift and 1.030 for end of shift were selected; workers exceeding these values were not allowed into the workplace (if the start of shift limit was exceeded) or were retested prior to their next working shift (if the end of shift limit was exceeded). A target of 1.015 as a euhydrated state for start of shift was adopted for workforce education. CONCLUSIONS This study found that "involuntary dehydration" did not occur in well informed workers, which has implications for heat stress standards that do not make provision for full fluid replacement during heat exposure. Fluid replacement during meal breaks was not significantly increased above fluid replacement rates during work time, with implications for the duration and spacing of meal breaks on long shifts. Testing of urinary specific gravity was found to be a good indication of hydration status and a practical method of improving workforce awareness and understanding of this important risk factor. Approximately 10 000 dehydration tests have been conducted under the dehydration protocol in a workforce of 2000 persons exposed to thermal stress and has proved practical and reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatigue in industrial workers under thermal stress on extended shift lengths.

A field investigation to examine the fatigue levels in industrial workers working extended (10, 12 and 12.5 h) shifts under significant levels of thermal stress was conducted on 45 male underground miners. Studies were conducted both before and after a major change to the working-in-heat protocol used at the operation. Prior to the change, shortened (6 h) shifts had been used when thermal condi...

متن کامل

تعیین و مقایسه شاخص های حرارتی TWLو WBGT در کارکنان یک دکل خشکی نفت-گاز در اهواز

Background and aims: Health hazards under heat stress conditions are well known and many industrial workers expose to heat stressful environments. Protection of the health of workers with suitable productivity is very important the idea requires adoption of a heat stress index that is both reliable and easy to use. Recent studies have found that Thermal Work Limit (TWL) performs better than W...

متن کامل

Hydration status and physiological workload of UAE construction workers: A prospective longitudinal observational study

BACKGROUND The objective of the study was to investigate the physiological responses of construction workers labouring in thermally stressful environments in the UAE using Thermal Work Limit (TWL) as a method of environmental risk assessment. METHODS The study was undertaken in May 2006. Aural temperature, fluid intake, and urine specific gravity were recorded and continuous heart rate monito...

متن کامل

Hydration status of expatriate manual workers during summer in the middle East.

BACKGROUND Implicit in all indices used for risk assessment in the prevention of heat stress is the assumption that workers are healthy and well hydrated; studies in Australian mine workers have shown that this is not the case. Where workers are poorly hydrated, the level of protection offered by management strategies based primarily on environmental monitoring is compromised. OBJECTIVES To i...

متن کامل

Physiological strain of miners at hot working places in German coal mines.

As the percentage of shifts in hot working conditions in German Coal mines had increased to more than 50% during the last decade, a study was carried out to record the physiological strain of miners. Thirty-eight miners participated during 125 shifts. Heart rate and rectal temperature were measured continuously. Sweat losses as well as food and fluid uptake were estimated from measurements befo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 60 2  شماره 

صفحات  -

تاریخ انتشار 2003