Relevant In Vitro Predictors of Human Acellular Dermal Matrix-Associated Inflammation and Capsule Formation in a Nonhuman Primate Subcutaneous Tissue Expander Model

نویسندگان

  • Maryellen Sandor
  • Patrick Leamy
  • Pearl Assan
  • Amardeep Hoonjan
  • Li-Ting Huang
  • Marianne Edwards
  • Wenqi Zuo
  • Hui Li
  • Hui Xu
چکیده

Objective: Benchtop methods were evaluated for preclinical inflammation/capsule formation correlation following implantation of human acellular dermal matrices. Methods: Dermal matrices were compared with native dermis for structure (histology, scanning electron microscopy), collagen solubility (hydroxyproline), enzymatic susceptibility (collagenase), and thermal stability (differential scanning calorimetry). Results were compared with implantation outcomes in a primate tissue expander model. Results: Native dermis, electron beam-sterilized, and freeze-dried human acellular dermal matrices had equivalent morphology, acid-soluble collagen (60.5% ± 6.3%, 65.3% ± 3.2%, and 63.3% ± 2.4%, respectively), and collagenase resistance. Implant results showed minimal inflammation/matrix degradation, lack of capsule formation, insignificant elastic modulus change (57.65 ± 20.24 MPa out-of-package/44.84 ± 23.87 MPa in vivo), and low antibody induction (2- to 8-fold increase) for electron beam-sterilized matrix. Similar results for freeze-dried dermal matrix were previously observed. γ-Irradiated, γ-irradiated/freeze-dried, and ethanol-stored dermal matrices were statistically different from native dermis for acid-soluble collagen (82.4% ± 5.8%, 72.2% ± 6.2%, and 76.8% ± 5.0%, respectively) and collagenase digestion rate, indicating matrix damage. γ-Irradiated matrix-implanted animals demonstrated elevated inflammatory response, foreign body giant cells, capsule formation at the tissue expander junction, and robust matrix metalloproteinase-1 staining with significant elastic modulus decrease (37.43 ± 7.52 MPa out-of-package/19.58 ± 1.16 MPa in vivo). Antibody increase (32- to 128-fold) was observed 6 to 10 weeks following γ-irradiated matrix implantation. Ethanol-stored dermal matrix elicited an acute antibody response (4- to 128-fold increase, 2-4 weeks) and macrophage-concentrated synovial-like hyperplasia at the tissue expander junction, moderate matrix metalloproteinase-1 staining, and significant elastic modulus decrease (61.15 ± 9.12 MPa out-of-package/17.92 ± 4.02 MPa in vivo) by 10 weeks implantation. Conclusion: Demonstrated loss of collagen integrity in vitro may be predictive of inflammation/capsule formation in primate tissue expander models. These results may be further predictive of clinical observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Host Response of 2 Human Acellular Dermal Matrices in a Primate Implant Model

OBJECTIVE We examined the differences in capsule formation between 2 commercially available human acellular dermal matrices in a nonhuman primate model. METHODS Primates were implanted dorsally with a subcutaneously placed tissue expander and randomized into 3 groups, receiving skin coverage only, coverage with non-irradiated freeze-dried human acellular dermal matrix, or coverage with gamma-...

متن کامل

Management of a Case of Mucor Colonization in Breast Tissue Expander Seroma Pocket

Mucormycosis has a mortality rate reaching 90%, and is imperative that therapy be initiated rapidly once a diagnosis is made.  Successful treatment consists of management of underlying risk factors, surgical debridement, and antifungal therapies. The dilemma whether or not to pursue extensive debridement presents when the wound is cultured positive but the patient is not systemically ill.&...

متن کامل

Analysis of the National Surgical Quality Improvement Program database in 19,100 patients undergoing implant-based breast reconstruction: complication rates with acellular dermal matrix.

BACKGROUND The use of acellular dermal matrices has become increasingly popular in immediate and delayed tissue expander/implant-based breast reconstruction. However, it is unclear whether their use is associated with increased postoperative complication rates. Using the American College of Surgeons National Surgical Quality Improvement Program database, the authors assessed baseline difference...

متن کامل

Complications Following Expander/Implant Breast Reconstruction Utilizing Acellular Dermal Matrix: A Systematic Review and Meta-Analysis

BACKGROUND The recent increase in popularity of acellular dermal matrix assistance in immediate expander/implant breast reconstruction has led to variety of viewpoints. Many studies are published indicating an increase in complications with the use of acellular dermal matrix, while others indicate there is no increase in complications. METHODS This meta-analysis utilizes information from avai...

متن کامل

Results of Acellular Dermis Matrix Graft Used for Tympanoplasty in Guinea Pig Model

Introduction: To describe the underlay tympanoplasty technique using an acellular dermal graft(AlloDerm) for tympanic membrane (TM) reconstruction in a guinea pig model and to demonstrate the feasibility of the technique using AlloDerm tissue harvested from the prepuce as a source of tissue for future grafting in human TM reconstruction.   Materials and Methods: The prepuce was divided during c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017