A Convenient RP-HPLC Method for Assay Bioactivities of Angiotensin I-Converting Enzyme Inhibitory Peptides

نویسندگان

  • Wei Wang
  • Nan Wang
  • Yu Zhang
  • Zheng Cai
  • Qihe Chen
  • Guoqing He
چکیده

A convenient and accurate reversed-phase high-performance liquid chromatography (RP-HPLC) method for angiotensin I-converting enzyme inhibitory peptides assay was described in this paper. The mobile phase consisted of 70% A (0.05% TFA and 0.05% triethylamine in water, pH = 2.9-3.3) and 30% B (100% acetonitrile) using an Isogradient program. The flow rate was 0.5 mL/min. The absorb wavelength was 226.5 nm; the column temperature was controlled at 25°C. This method for angiotensin I-converting enzyme inhibitory peptides assay was convenient for the Iso-gradient program. The accuracy of the RT-HPLC method was verified by analyzing ACE inhibitory activity of the hydrolysate peptides of silkworm pupae protein, and the results showed that the RT-HPLC method was available for exploring new source of angiotensin I-converting enzyme inhibitory peptides rapidly and veraciously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of analytical methods to assay inhibitors of angiotensin I-converting enzyme.

The linearity, precision and repeatability of visible spectrophotometric (VSP) and high-performance liquid chromatography (HPLC) methods for analysis of inhibitory activity of angiotensin I-converting enzyme (ACE) were compared by using several inhibitors and Hip-His-Leu (HHL) as substrates. IC50 values (concentration at which ACE activity is inhibited by 50%) of 0.00206±0.00005 μg/mL for capto...

متن کامل

A HPLC-UV method for the determination of angiotensin I-converting enzyme (ACE) inhibitory activity

To determine the angiotensin-converting enzyme (ACE) inhibitory activity of a fish hydrolysate, different methods were tested. Finally, a sensitive, extraction-free HPLC method using N-(3-[2-furylacryloyl)-PheGly-Gly (FAPGG) as substrate was preferred. This method relies on the UV-titration of the peptide 2-furylacryloyl-L-Phe (FAP) resulting from the hydrolysis of the FAPGG after a chromatogra...

متن کامل

Kinetics of the inhibition of renin and angiotensin I-converting enzyme by cod (Gadus morhua) protein hydrolysates and their antihypertensive effects in spontaneously hypertensive rats

BACKGROUND Cod muscle has a balanced protein profile that contains potentially bioactive amino acid sequences. However, there is limited information on release of these peptides from the parent proteins and their ability to modulate mammalian blood pressure. OBJECTIVE The aim of this study was to generate cod antihypertensive peptides with potent in vitro inhibitory effects against angiotensi...

متن کامل

Thermo-, Radio- and Photostability of Perindopril Tert-butyloamine in The Solid State. Comparison to Other Angiotensin Converting Enzyme Inhibitors

The main aim of this study was determination of thermo- radio- and photostability ofperindopril tert-butyloamine (PER) therefore the efficiency and safety of the therapy could bemaintained.A chromatographic method (RP-HPLC) had been validated before use to determinePER loss. The evaluation of stability properties of PER in solid state under the influence ofisothermal condition, relative humidit...

متن کامل

Thermo-, Radio- and Photostability of Perindopril Tert-butyloamine in The Solid State. Comparison to Other Angiotensin Converting Enzyme Inhibitors

The main aim of this study was determination of thermo- radio- and photostability ofperindopril tert-butyloamine (PER) therefore the efficiency and safety of the therapy could bemaintained.A chromatographic method (RP-HPLC) had been validated before use to determinePER loss. The evaluation of stability properties of PER in solid state under the influence ofisothermal condition, relative humidit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013