One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon.

نویسندگان

  • Andreas Metzner
  • Bruno Reissmann
  • Peter Rausch
  • Shibu Mathew
  • Peter Wohlmuth
  • Roland Tilz
  • Andreas Rillig
  • Christine Lemes
  • Sebastian Deiss
  • Christian Heeger
  • Masashi Kamioka
  • Tina Lin
  • Feifan Ouyang
  • Karl-Heinz Kuck
  • Erik Wissner
چکیده

BACKGROUND The use of second-generation cryoballoon for pulmonary vein isolation in patients with paroxysmal atrial fibrillation has demonstrated encouraging acute and mid-term results. Long-term outcome data are not yet available. METHODS AND RESULTS Fifty patients (18 women; mean age, 61±11 years; mean left atrial diameter, 43±5 mm) with paroxysmal (36 of 50 patients; 72%) or short-standing (<3-month duration) persistent atrial fibrillation (14 of 50 patients; 28%) underwent cryoballoon-based pulmonary vein isolation. Freeze cycle duration was 240 seconds. After successful pulmonary vein isolation, a bonus freeze was applied. Follow-up was based on outpatient clinic visits at 3, 6, and 12 months including Holter-ECGs and telephonic interviews. Recurrence was defined as a symptomatic or documented arrhythmia episode>30 seconds excluding a 3-month blanking period. A total of 192 pulmonary veins were identified, and 191 of 192 (99%) pulmonary veins were successfully isolated. Phrenic nerve palsy occurred in 1 of 50 (2%) patients. Follow-up was available for 49 of 50 (98%) patients with a mean follow-up duration of 440±39 days. Thirty-nine of 49 (80%) patients remained in stable sinus rhythm. Of 8 of 10 patients with arrhythmia recurrence, a second procedure using radiofrequency ablation demonstrated left atrial to pulmonary vein reconduction. CONCLUSIONS The use of second-generation 28-mm cryoballoon for pulmonary vein isolation results in an 80% 1-year success rate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: a retrospective analysis.

AIMS The purpose of this study was to determine efficacy of pulmonary vein isolation (PVI) using the 28 mm cryoballoon (CB) in patients with persistent atrial fibrillation (AF). Superior acute and 1-year outcome has been demonstrated following PVI, using the second-generation CB in patients with paroxysmal AF. Data on the outcome in patients with persistent AF are sparse. METHODS AND RESULTS ...

متن کامل

Once Isolated, Always Isolated? Incidence and Characteristics of Pulmonary Vein Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation.

BACKGROUND The second-generation cryoballoon delivers effective pulmonary vein isolation (PVI) associated with superior 1-year clinical outcome. However, data on reconduction of previously isolated PV are sparse. METHODS AND RESULTS A total of 421 patients underwent second-generation 28-mm cryoballoon-based PVI in 2 centers (St. George's hospital and Harburg hospital, Hamburg, Germany) betwee...

متن کامل

Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon.

BACKGROUND The differences in ablation characteristics of freezing time and balloon size using second generation cryoballoon are still unknown. METHODS AND RESULTS Twenty-six dogs underwent pulmonary vein (PV) isolation. Balloon and tissue temperatures (left atrial-PV junction, phrenic nerve, and internal esophagus) were monitored. The ablation duration was randomized to either 3 or 4 minutes...

متن کامل

On the Quest for the Best Freeze: Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation.

BACKGROUND The second-generation cryoballoon is effective in achieving acute pulmonary vein isolation (PVI) and favorable clinical outcome. To date, no data are available on factors affecting late PV reconnection after second-generation cryoballoon ablation. METHODS AND RESULTS A total of 29 consecutive patients (25 male, 86.2%; mean age 57.8±13.8 years) underwent a repeat procedure, after a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2014