Real Time 3D echocardiography (RT3D) for assessment of ventricular and vascular function in hypertensive and heart failure patients
نویسندگان
چکیده
BACKGROUND Cardiac and systemic hemodynamics have been historically in the domain of invasive cardiology, but recent advances in real-time 3-Dimensional echocardiography (RT3D echo) provide a reliable measurement of ventricular volumes, allowing to measure a set of hemodynamic parameters previously difficult or impossible to obtain with standard 2D echo. AIM To assess the feasibility of a comprehensive hemodynamic study with RT-3D echo. METHODS We enrolled 136 patients referred for routine echocardiography: 44 normal (N), 57 hypertensive (HYP), and 35 systolic heart failure patients (HF). All patients underwent standard 2D echo examination followed by RT3D echo examination, including measurement of left ventricular (LV) end-diastolic and end-systolic volumes and derived assessment of LV elastance (an index of LV contractility), arterial elastance (characterizing the distal impedance of the arterial system downstream of the aortic valve); ventricular-arterial coupling (a central determinant of net cardiovascular performance); systemic vascular resistances. Blood pressure was derived from cuff sphygmomanometer and heart rate from ECG. RESULTS A complete 2D echo was performed in all 136 patients. 3D echo examination was obtained in 130 patients (feasibility = 95 %). Standard 2D echo examination was completed in 14.8 ± 2.2 min. Acquisition of 3D images required an average time of 5 ± 0.9 min (range 3.5-7.5 min) and image analysis was completed in 10.1 ± 2.8 min (range 6-12 min) per patient. Compared to N and HYP, HF patients showed reduced LV elastance (1.7 ± 1.5 mmHg mL(-1) m(-2), p < 0.001 vs N = 3.8 ± 1.3 and HYP = 3.8 ± 1.3) and ventricular-arterial coupling (0.6 ± 0.5, p < 0.01 vs N = 1.4 ± 0.4 and HYP = 1.2 ± 0.4). Systemic vascular resistances were highest in HYP (2736 ± 720, p < .01 vs N = 1980 ± 432 and vs HF = 1855 ± 636 dyne*s/cm5). The LV elastance was related to EF (r = 0.73, p < 0.01) and arterial pressure was moderately related to vascular elastance (r = 0.54, p < 0.01). The ventricular-arterial coupling was unrelated to systemic vascular resistances (r = -0.04, p NS). CONCLUSION RT-3D echo allows a non invasive, comprehensive assessment of cardiac and systemic hemodynamics, offering insight access to key variables--such as increased systemic vascular resistances in hypertensives and reduced ventricular-arterial coupling in heart failure patients.
منابع مشابه
Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience
AIM OF THE WORK To evaluate the feasibility and possible additional value of transthoracic real-time three-dimensional echocardiography (RT3D-TTE) for the assessment of cardiac structures as compared to 2D-TTE. METHODS 320 patients (mean age 45 ± 8.4 years, 75% males) underwent 2D-TTE and RT3D-TTE using 3DQ-Q lab software for offline analysis. Volume quantification and functional assessment w...
متن کاملFast measurement of left ventricular mass with real-time three-dimensional echocardiography: comparison with magnetic resonance imaging.
BACKGROUND Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data se...
متن کاملTranscathether Valve Replacement and Valve Repair
According to the American Heart Association/American College of Cardiology Guidelines for the Management of Patients with Valvular Heart Disease, echocardiography (transthoracic echocardiography [TTE] or transesophageal echocardiography [TEE]) is the imaging modality of choice for the assessment of valvular heart disease in patients. Numerous less invasive therapies such as percutaneous or tran...
متن کاملFeasibility of real-time three-dimensional stress echocardiography: pharmacological and semi-supine exercise
BACKGROUND Real time three dimensional (RT3D) echocardiography is an accurate and reproducible method for assessing left ventricular shape and function. AIM assess the feasibility and reproducibility of RT3D stress echocardiography (SE) (exercise and pharmacological) in the evaluation of left ventricular function compared to 2D. METHODS AND RESULTS One hundred eleven patients with known or ...
متن کاملEffects of Decreased Annular Height and Annular Saddle-Shaped Non-Planarity in Degenerative Severe Mitral Regurgitation with Normal Left Ventricular Ejection Fraction: Real-Time 3D Transesophageal Echocardiography
BACKGROUND The extent of mitral annular (MA) remodeling and dysfunction is correlated with the severity of mitral regurgitation (MR) as well as left atrial (LA) and left ventricular (LV) dilation. MA dysfunction may be a useful prognostic factor for operative timing and MR recurrence after successful mitral valve (MV) repair. The aim of this study was to evaluate additive prognostic factors of ...
متن کامل