Evaluating the depth of the epidural space with the use of ultrasound.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES The objective of the present study was to evaluate the use of the ultrasound on the determination of the depth of the epidural space. METHODS Sixty patients were included in this prospective study; the L(3)-L(4) space was initially identified by palpation followed by the ultrasound measuring the depth of the epidural space (PU). After the epidural puncture the measurements o the depth (PA) were recorded. The data underwent descriptive statistics, and the concordance correlation coefficient and Bland-Altman analysis, with 95% confidence interval were calculated. RESULTS Analysis of concordance between the palpation and ultrasound methods was 86.6%. Mean values of PU obtained were 4.97 +/- 0.51 cm and PA 4.97 +/- 0.71 cm, and Pearson correlation coefficient of 0.66 while Bland-Altman analysis revealed a mean difference of 0.0035 +/- 0.53 cm with 95% confidence interval between -0.228 and 0.221. CONCLUSIONS The ultrasound is a precise tool to determine the depth of the epidural space.
منابع مشابه
Epidural Catheter Placement in Morbidly Obese Parturients with the Use of an Epidural Depth Equation prior to Ultrasound Visualization
BACKGROUND Previously, Balki determined the Pearson correlation coefficient with the use of ultrasound (US) was 0.85 in morbidly obese parturients. We aimed to determine if the use of the epidural depth equation (EDE) in conjunction with US can provide better clinical correlation in estimating the distance from the skin to the epidural space in morbidly obese parturients. METHODS One hundred ...
متن کاملThe Use of Ultrasound to Measure the Depth of Thoracic Epidural Space
The use of ultrasound to aid in regional blocks has increased in recent years as a result of improvement in ultrasound technology. Ultrasonography can be used to measure the depth of thoracic epidural spacewith a good correlation with the actual depth as detected by the loss of resistance technique.
متن کاملAnalgesic Effect of a Single Dose of Adenosine for Neuropathic Pain Reduction in a Patient with Primitive Neuroechtodermal Tumor
Background: We report the analgesic efficacy of lumbar epidural adenosine injection in reducing the chronic neuropathic pain in a patient with primitive neuroectodermal tumor. Report of the Case: In this case report a 13-year-old male with primary neuroectodermal tumor (PNET) was administered in epidural space with adenosine to reduce his pain. The patient received 10ml of 0.25% ropivacaine ...
متن کاملUltrasound-guided epidural blood patch.
A 35-YR-OLD woman presented with a postdural puncture headache for epidural blood patch. The procedure was performed in the lateral position. A curvilinear ultrasound probe with sterile cover was used to visualize the epidural space. A 20-G epidural needle was used to identify the space by the loss-of-resistance technique. Blood was then injected into the epidural space under real-time ultrasou...
متن کاملInflammatory Pseudotumor in the Epidural Space of the Lumbosacral Spine on F-18 FDG PET/CT
An inflammatory pseudotumor (IPT) is a rare benign lesion, characterized by nonneoplastic proliferation of inflammatory cells and presence of intermingling collagen fibers. IPT commonly occurs in the lungs and orbita, while an intraspinal IPT is extremely rare. IPT can mimic both clinically and radiologically malignant processes, and making a definitive preoperative diagnosis is often difficult...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de anestesiologia
دوره 60 4 شماره
صفحات -
تاریخ انتشار 2010